升主动脉瘤修复 44 年后 Starr-Edwards 笼球主动脉瓣置换。

Ascending aortic aneurysm repair 44 years after Starr-Edwards caged-ball aortic valve replacement.

机构信息

Department of Surgery, McGovern Medical School at The University of Texas Health Science Center at Houston (UTHealth), Houston, TX, USA.

Department of Cardiothoracic and Vascular Surgery, McGovern Medical School at The University of Texas Health Science Center at Houston (UTHealth), Houston, TX, USA.

出版信息

Eur J Cardiothorac Surg. 2018 Nov 1;54(5):962-963. doi: 10.1093/ejcts/ezy161.

Abstract

We report a case of ascending aortic aneurysm repair and redo aortic valve replacement with a bioprosthesis 44 years after aortic valve replacement with a Starr-Edwards metal caged-ball prosthesis. The patient presented with a moderately stenotic caged-ball valve and a 50-mm ascending aortic aneurysm on a routine follow-up transthoracic echocardiography. We replaced the valve with a bioprosthesis at the time of aortic repair as the patient wished to stop anticoagulation therapy. Intraoperatively, we found that the cloth covering of the cage was nearly completely destroyed.

摘要

我们报告了一例升主动脉瘤修复和再次主动脉瓣置换的病例,该患者在接受 Starr-Edwards 金属笼球瓣置换术后 44 年再次接受生物瓣置换。该患者在常规经胸超声心动图随访时发现中度狭窄的笼球瓣和 50mm 的升主动脉瘤。由于患者希望停止抗凝治疗,我们在主动脉修复时更换了生物瓣。术中发现,笼的布罩几乎完全损坏。

相似文献

1
Ascending aortic aneurysm repair 44 years after Starr-Edwards caged-ball aortic valve replacement.
Eur J Cardiothorac Surg. 2018 Nov 1;54(5):962-963. doi: 10.1093/ejcts/ezy161.
2
Ascending aortic aneurysm in a patient with an aortic Starr-Edwards ball valve prosthesis implanted 39 years previously.
Gen Thorac Cardiovasc Surg. 2010 Mar;58(3):138-40. doi: 10.1007/s11748-009-0504-3. Epub 2010 Mar 28.
3
Reoperation for aortic homograft failure using an Edwards Intuity valve.
Interact Cardiovasc Thorac Surg. 2016 Mar;22(3):378-80. doi: 10.1093/icvts/ivv343. Epub 2015 Dec 15.
4
3D-printing assisted closure of paravalvular leak.
J Cardiovasc Comput Tomogr. 2020 Sep-Oct;14(5):e66-e68. doi: 10.1016/j.jcct.2019.03.008. Epub 2019 Mar 26.
5
Sutureless aortic bioprosthesis valve implantation and bicuspid valve anatomy: an unsolved dilemma?
Heart Vessels. 2016 Nov;31(11):1783-1789. doi: 10.1007/s00380-015-0790-x. Epub 2016 Jan 12.
6
Long-term prognosis of ascending aortic aneurysm after aortic valve replacement for bicuspid versus tricuspid aortic valve stenosis.
J Thorac Cardiovasc Surg. 2014 Jan;147(1):276-82. doi: 10.1016/j.jtcvs.2012.11.004. Epub 2012 Dec 13.
8
Congenital bicuspid pulmonary valve. An uncommon impede for Ross procedure.
Acta Chir Belg. 2017 Apr;117(2):115-117. doi: 10.1080/00015458.2016.1220121. Epub 2016 Aug 22.
9
Aortic Valve Reoperation After Stentless Bioprosthesis: Short- and Long-Term Outcomes.
Ann Thorac Surg. 2018 Aug;106(2):521-525. doi: 10.1016/j.athoracsur.2018.02.073. Epub 2018 Apr 3.
10

引用本文的文献

1
Stanford A aortic dissection 40 years after aortic valve replacement with a Starr-Edwards caged-ball prosthesis: a case report.
J Surg Case Rep. 2024 Nov 16;2024(11):rjae707. doi: 10.1093/jscr/rjae707. eCollection 2024 Nov.

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验