Suppr超能文献

通过频率稳定腔衰荡光谱法测量的2μm波长区域的高精度一氧化碳(CO)谱线强度。

High-accuracy CO line intensities in the 2 μm wavelength region measured by frequency-stabilized cavity ring-down spectroscopy.

作者信息

Yi Hongming, Liu Qingnan, Gameson Lyn, Fleisher Adam J, Hodges Joseph T

机构信息

National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899, U.S.A.

出版信息

J Quant Spectrosc Radiat Transf. 2018 Feb;206:367-377. doi: 10.1016/j.jqsrt.2017.12.008. Epub 2017 Dec 13.

Abstract

Reported here are highly accurate, experimentally measured ro-vibrational transition intensities for the R-branch of the (20012) - (00001) CO band near = 2 μm. Measurements were performed by a frequency-stabilized cavity ring-down spectroscopy (FS-CRDS) instrument designed to achieve precision molecular spectroscopy in this important region of the infrared. Through careful control and traceable characterization of CO sample conditions, and through high-fidelity measurements spanning several months in time, we achieve relative standard uncertainties for the reported transition intensities between 0.15 % and 0.46 %. Such high accuracy spectroscopy is shown to provide a stringent test of calculated potential energy and dipole moment surfaces, and therefore transition intensities calculated from first principles.

摘要

本文报道了在波长约2μm附近的(20012)-(00001)CO带R支的高精确实验测量的振转跃迁强度。测量由一台频率稳定腔衰荡光谱仪(FS-CRDS)完成,该仪器旨在实现红外这一重要区域的精密分子光谱。通过对CO样品条件的仔细控制和可溯源表征,以及经过数月的高保真测量,我们得到所报道跃迁强度的相对标准不确定度在0.15%至0.46%之间。这种高精度光谱被证明能对计算的势能和偶极矩面进行严格检验,从而也能对从第一性原理计算出的跃迁强度进行严格检验。

相似文献

1
High-accuracy CO line intensities in the 2 μm wavelength region measured by frequency-stabilized cavity ring-down spectroscopy.
J Quant Spectrosc Radiat Transf. 2018 Feb;206:367-377. doi: 10.1016/j.jqsrt.2017.12.008. Epub 2017 Dec 13.
6
Ames-2021 CO Dipole Moment Surface and IR Line Lists: Toward 0.1% Uncertainty for CO IR Intensities.
J Phys Chem A. 2022 Sep 8;126(35):5940-5964. doi: 10.1021/acs.jpca.2c01291. Epub 2022 Aug 25.
8
Optical feedback frequency stabilized cavity ring-down spectroscopy.
Opt Lett. 2014 Aug 15;39(16):4695-8. doi: 10.1364/OL.39.004695.

引用本文的文献

4
Twenty-Five-Fold Reduction in Measurement Uncertainty for a Molecular Line Intensity.
Phys Rev Lett. 2019 Jul 26;123(4):043001. doi: 10.1103/PhysRevLett.123.043001.
5
Optical Measurement of Radiocarbon below Unity Fraction Modern by Linear Absorption Spectroscopy.
J Phys Chem Lett. 2017 Sep 21;8(18):4550-4556. doi: 10.1021/acs.jpclett.7b02105. Epub 2017 Sep 11.

本文引用的文献

1
Highly accurate intensity factors of pure CO lines near 2 μm.
J Chem Phys. 2017 Jun 28;146(24):244309. doi: 10.1063/1.4989925.
2
Precision Interferometric Measurements of Mirror Birefringence in High-Finesse Optical Resonators.
Phys Rev A (Coll Park). 2016 Jan;93(1). doi: 10.1103/physreva.93.013833. Epub 2016 Jan 19.
3
High-Accuracy CO(2) Line Intensities Determined from Theory and Experiment.
Phys Rev Lett. 2015 Jun 19;114(24):243001. doi: 10.1103/PhysRevLett.114.243001. Epub 2015 Jun 15.
5
Laser bandwidth effects in quantitative cavity ring-down spectroscopy.
Appl Opt. 1996 Jul 20;35(21):4112-6. doi: 10.1364/AO.35.004112.
8
Line strengths of N2O in the 1120-1440-cm-1 region.
Appl Opt. 1984 Jun 1;23(11):1825. doi: 10.1364/ao.23.001825.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验