The performance of knitted Dacron and polytetrafluoroethylene (PTFE) bifurcated grafts are compared in this study of 312 patients at a single institution. Patients of the two graft groups were statistically well-matched in risk factors and degree of distal obstructive disease. Operating time needed to implant either graft was approximately equal. For patients with abdominal aortic aneurysms, mean volume of blood transfused was 2.2 units for Dacron grafts and 0.2 units for PTFE grafts; for patients with aortoiliac occlusive disease, the comparable figures were 1.1 units and 0.1 units, respectively. Four-year cumulative patency for Dacron (90%) and PTFE (97%) grafts were not significantly different (p greater than 0.01). Complications affected 13% of the patients of the Dacron group and 4% of the PTFE group. All six graft infections and all seven graft double-limb thromboses occurred in Dacron grafts. Anastomotic aneurysms, amputations, and late graft revisions occurred with greater frequency in patients with Dacron grafts.
在这家单一机构对312例患者进行的这项研究中,对针织涤纶和聚四氟乙烯(PTFE)分叉移植物的性能进行了比较。两个移植物组的患者在危险因素和远端阻塞性疾病程度方面在统计学上匹配良好。植入任何一种移植物所需的手术时间大致相等。对于腹主动脉瘤患者,涤纶移植物的平均输血量为2.2单位,PTFE移植物为0.2单位;对于主髂动脉闭塞性疾病患者,相应数字分别为1.1单位和0.1单位。涤纶(90%)和PTFE(97%)移植物的四年累积通畅率无显著差异(p大于0.01)。并发症在涤纶组患者中占13%,在PTFE组患者中占4%。所有6例移植物感染和所有7例移植物双肢血栓形成均发生在涤纶移植物中。涤纶移植物患者发生吻合口动脉瘤、截肢和晚期移植物翻修的频率更高。