Suppr超能文献

单侧保留双交叉韧带全膝关节置换术后膝关节运动对称性未恢复:体内三维运动学分析。

Knee motion symmetry was not restored in patients with unilateral bi-cruciate retaining total knee arthroplasty-in vivo three-dimensional kinematic analysis.

机构信息

Department of Orthopaedic Surgery, Harvard Medical School, Massachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA.

出版信息

Int Orthop. 2018 Dec;42(12):2817-2823. doi: 10.1007/s00264-018-3986-8. Epub 2018 May 19.

Abstract

PURPOSE

Although unilateral total knee arthroplasty (TKA) is successful in restoring function, there are concerns in relation to asymmetric gait patterns. Bi-cruciate retaining (BCR) TKA design preserves both anterior and posterior cruciate ligaments with the potential to restore normal joint kinematics. The purpose of this study was to investigate the in vivo three-dimensional (3D) kinematics of the knee in unilateral BCR TKA patients during gait.

METHODS

Twenty-nine unilateral BCR TKA patients were evaluated for both knees during treadmill gait using a combined computer tomography and dual fluoroscopic imaging system approach.

RESULTS

Significantly higher flexion (4 ± 6.7°) and internal rotation (4.3 ± 4.7°) and significantly lower adduction (2.5 ± 4.4°) during the stance phase of gait cycle were observed in the implanted side of unilateral BCR TKA patients. Significant asymmetric lateral/medial (3.2 ± 4.8 mm) and anterior/posterior (3.4 ± 4.1 mm) tibial translations were also measured during treadmill gait in this cohort of patients.

CONCLUSION

Despite maintaining anteroposterior stability, asymmetric knee motion persisted in in vivo unilateral BCR TKA patients during gait. The results of the current study suggested that the knee motion symmetry during gait was not restored in patients with unilateral BCR TKA.

摘要

目的

尽管单侧全膝关节置换术(TKA)在恢复功能方面取得了成功,但人们对不对称步态模式仍存在担忧。保留双交叉韧带(BCR)的 TKA 设计保留了前交叉韧带和后交叉韧带,有潜力恢复正常的关节运动学。本研究的目的是研究单侧 BCR TKA 患者在步态中膝关节的体内三维(3D)运动学。

方法

使用计算机断层扫描和双荧光透视成像系统联合评估了 29 例单侧 BCR TKA 患者双侧膝关节在跑步机上行走时的情况。

结果

单侧 BCR TKA 患者在步态的站立相时,植入侧的膝关节屈曲(4±6.7°)和内旋(4.3±4.7°)显著增加,而内收(2.5±4.4°)显著减少。在这组患者中,在跑步机上行走时,还测量到胫骨明显的不对称外侧/内侧(3.2±4.8mm)和前/后(3.4±4.1mm)平移。

结论

尽管维持了前后稳定性,但在体内单侧 BCR TKA 患者的步态中仍存在膝关节运动不对称。本研究结果表明,单侧 BCR TKA 患者的步态膝关节运动对称性未恢复。