In this Article, a compact Fourier transform ion cyclotron resonance (FTICR) mass spectrometer based on a permanent magnet is presented. This instrument has been developed for real-time analysis of gas emissions. The instrument is well-suited to industrial applications or analysis of toxic and complex samples where the concentrations can vary rapidly on a wide range. The novelty of this instrument is the ability to use either electron ionization (EI) or chemical ionization (CI) individually or both of them alternatively. Also in CI mode, different precursor ions can be used alternatively. Volatile organic compounds (VOCs) from the ppb level to very high concentrations (% level) can be detected by CI or EI. The magnet is composed of three Halbach arrays, and the nominal field achieved is 1.5 T. The ICR cell is a 3 cm side length cubic cell. The mass range is 12-200 u with a broad band detection. The mass accuracy of 0.005 u and the resolving power allow the separation of isobaric ions such as CH and CO. Gas introduction via controlled gas pulses, electron ionization, ion-molecule reactions, ion selection, and detection are all performed in the ICR cell. The potential of the instrument will be illustrated by an analysis of a gas mixture containing trace components at ppm level (VOCs) and components in the 0.5-100% range (N, alkanes, and CO).

摘要

本文介绍了一种基于永磁体的紧凑傅里叶变换离子回旋共振(FTICR)质谱仪。该仪器是为实时分析气体排放而开发的。该仪器非常适合工业应用或分析毒性和复杂的样品,其中浓度可以在很宽的范围内快速变化。该仪器的新颖之处在于能够单独使用电子电离(EI)或化学电离(CI),或者交替使用这两种方法。在 CI 模式下,也可以交替使用不同的前体离子。挥发性有机化合物(VOC)可以从 ppb 级到非常高的浓度(%级)通过 CI 或 EI 进行检测。磁铁由三个 Halbach 阵列组成,达到的标称场强为 1.5 T。ICR 池是一个边长为 3 厘米的立方池。质量范围为 12-200 u,具有宽带检测。质量精度为 0.005 u,分辨率允许分离如 CH 和 CO 等等摩尔离子。通过受控气体脉冲、电子电离、离子-分子反应、离子选择和检测,在 ICR 池中进行气体引入。该仪器的潜力将通过分析含有痕量成分(VOC)的ppm 级(VOCs)和 0.5-100%(N、烷烃和 CO)范围内的成分的气体混合物来说明。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验