Short-Term Deposition of PM Particles on Contact Lens Surfaces: Effect on Oxygen Permeability and Refractive Index.

机构信息

b Department of Ophthalmology , The Seconnd affiliated hospital & Yuying Children's hospital of Wenzhou Medical University , Wenzhou , China.

c Department of Ophthalmology , Xi'an No.3 Hospital, Xi'an , Shaanxi Province , China.

出版信息

Curr Eye Res. 2018 Sep;43(9):1102-1107. doi: 10.1080/02713683.2018.1476552. Epub 2018 Jun 5.

Abstract

PURPOSES

To identify the deposition of fine (≤2.5 μm diameter) particulate matter (PM) particles (PM) on contact lens surfaces and to investigate the effects of such deposition on the oxygen permeability (OP) and refractive index (RI) of contact lenses.

METHODS

A total of 36 contact lenses, including rigid gas permeable (RGP) lens and soft contact lens (SCL), were investigated. RGP lens (n=12) and SCL (n=12) (experimental group) were incubated in a PM solution for 24 h, after which PM-treated RGP lens (n=6) and SCL (n=6) were further washed for 1 h in phosphate-buffered saline (PBS). All lenses were examined by field emission scanning electron microscopy. OP and RI of all lenses were measured.

RESULTS

Average-sized PM particles deposited on RGP contact lens and SCL surfaces after immersion in the PM solution were 3.192 ± 1.637 and 2.158 ± 1.187/100 μm, respectively. On RGP lens surfaces, we observed both large (≥2.5 µm diameter) and small (PM) particles. PM particles were deposited in diffuse patterns, primarily along the honeycomb structural border of SCL, while no PM particles were found in the honeycomb hole of SCL surfaces. Washing in PBS removed the larger PM particles from RGP lens surfaces, but left copious amounts of PM particles. In contrast, nearly all PM particles were removed from SCL surfaces after PBS washing. OP values of RGP lens and SCL appeared to be unchanged by PM deposition. RI values increased in both RGP lens and SCL groups after PM deposition. However, these increases were not statistically significant, suggesting that PM deposition itself does not cause fluctuations in contact lens RI.

CONCLUSIONS

Deposition of PM particles on contact lens surfaces varies according to lens material. PM particles deposited on SCL, but only large particles on RGP surfaces were able to be removed by washing in PBS and did not appear to alter OP and RI of either lens type.

摘要

目的

确定细小(≤2.5μm 直径)颗粒物(PM)在隐形眼镜表面的沉积,并研究这种沉积对隐形眼镜氧气透过率(OP)和折射率(RI)的影响。

方法

共研究了 36 个隐形眼镜,包括硬性透气性隐形眼镜(RGP)和软性隐形眼镜(SCL)。将 RGP 镜片(n=12)和 SCL(n=12)(实验组)浸泡在 PM 溶液中 24 小时,然后将 PM 处理后的 RGP 镜片(n=6)和 SCL(n=6)进一步在磷酸盐缓冲盐水(PBS)中清洗 1 小时。所有镜片均通过场发射扫描电子显微镜检查。测量所有镜片的 OP 和 RI。

结果

PM 溶液浸泡后,RGP 隐形眼镜和 SCL 表面平均沉积的 PM 颗粒大小分别为 3.192±1.637 和 2.158±1.187/100μm。在 RGP 镜片表面,我们观察到既有大(≥2.5μm 直径)又有小(PM)的颗粒物。PM 颗粒呈弥漫状沉积,主要沿 SCL 的蜂窝状结构边界,而 SCL 表面的蜂窝孔中没有 PM 颗粒。PBS 清洗可将较大的 PM 颗粒从 RGP 镜片表面去除,但仍残留大量的 PM 颗粒。相比之下,PBS 清洗后,几乎所有的 PM 颗粒都从 SCL 表面去除。PM 沉积对 RGP 镜片和 SCL 的 OP 值似乎没有影响。PM 沉积后,RGP 镜片和 SCL 组的 RI 值均增加。然而,这些增加没有统计学意义,表明 PM 沉积本身不会导致隐形眼镜 RI 的波动。

结论

PM 颗粒在隐形眼镜表面的沉积因镜片材料而异。PM 颗粒沉积在 SCL 上,但只有 PBS 清洗才能去除 RGP 表面的大颗粒,且对两种镜片类型的 OP 和 RI 均无影响。