Suppr超能文献

复位时不拍摄 X 线片对牙根位置的三维评估:一项概念验证研究。

Three-dimensional evaluation of root position at the reset appointment without radiographs: a proof-of-concept study.

机构信息

Division of Orthodontics, University of California San Francisco, 707 Parnassus Ave. d3000, San Francisco, CA, 94143, USA.

School of Dentistry, University of California San Francisco, San Francisco, CA, USA.

出版信息

Prog Orthod. 2018 Jun 4;19(1):15. doi: 10.1186/s40510-018-0214-4.

Abstract

BACKGROUND

Accurate root position is integral for successful orthodontic treatment. Current methods of monitoring root position are either inaccurate, exhibit poor resolution, or use relatively large amount of radiation relative to the benefits for the patient. The purpose of this study was to present an approach that can monitor root position during orthodontic treatment with minimal radiation.

METHODS

Cone-beam computed tomography (CBCT) scans were taken for a patient at pre-treatment and at a dedicated reset appointment. An extra-oral laser scan of a poured up cast was taken at the reset appointment. An expected root position (ERP) setup, an approximation of the root position at the reset appointment, was generated using the pre-treatment CBCT scan and reset appointment cast. The ERP setup was compared to the CBCT scan taken at the reset appointment which served as the control. Color displacement maps were generated to measure any differences between the expected and true root positions.

RESULTS

Color map displacement analysis after indirect superimposition found displacement differences of 0.021 mm ± 0.396 mm for the maxillary roots and 0.079 mm ± 0.499 mm for the mandibular roots.

CONCLUSIONS

This approach was demonstrated in a patient at the reset appointment to have the potential to accurately monitor root positions during treatment in three dimensions without the need for additional radiographs.

摘要

背景

准确的牙根位置对于成功的正畸治疗至关重要。目前监测牙根位置的方法要么不准确,分辨率差,要么相对患者的获益而言使用了相对较大剂量的辐射。本研究的目的是提出一种可以在正畸治疗期间使用最小辐射监测牙根位置的方法。

方法

在治疗前和专门的重置预约时为患者拍摄锥形束计算机断层扫描 (CBCT) 扫描。在重置预约时拍摄一个浇铸牙模的外部激光扫描。使用治疗前的 CBCT 扫描和重置预约牙模生成一个预期牙根位置 (ERP) 设置,这是重置预约时牙根位置的近似值。将 ERP 设置与重置预约时拍摄的 CBCT 扫描进行比较,该扫描作为对照。生成颜色位移图以测量预期和真实牙根位置之间的任何差异。

结果

间接叠加后的颜色图位移分析发现,上颌牙根的位移差异为 0.021 毫米±0.396 毫米,下颌牙根的位移差异为 0.079 毫米±0.499 毫米。

结论

本方法在重置预约时的患者中进行了演示,具有在不需要额外射线照片的情况下在三维空间中准确监测治疗期间牙根位置的潜力。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/75c2/5985242/323381b89fc2/40510_2018_214_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验