基于紫外光谱法实时测量聚砜膜透析器中聚乙烯吡咯烷酮的洗脱量。

Real-Time Measurement of Polyvinylpyrrolidone Eluted from Polysulfone Membrane Dialyzers Based on the Ultraviolet Spectrum.

机构信息

From the Yamamoto Clinic, Shin-nagata, Kobe, Japan.

Graduate School of Biomedical Engineering, Osaka Electro-Communication University, Shijonawate, Osaka, Japan.

出版信息

ASAIO J. 2019 Jul;65(5):522-526. doi: 10.1097/MAT.0000000000000829.

Abstract

The objective of this study was to develop a new method for measuring polyvinylpyrrolidone (PVP) eluted from polysulfone (PSu) membrane dialyzers. The Müller method is generally used for the measurement of PVP, in which the PVP concentration is determined by measuring the absorbance after a red color is generated by the formation of PVP-iodine complexes when iodine is added to a sample. In contrast, our method does not require any reagents and allows real-time measurement of PVP by the ultraviolet absorption spectrum (UV-s method). In this study, the UV-s method and the Müller method were used to measure PVP eluted from two types of PSu membrane dialyzer (PS-1.6UW sterilized by autoclaving [n = 10] and APS-15SA sterilized by gamma radiation [n = 10]). Polyvinylpyrrolidone concentrations measured by the two methods showed a significant positive correlation (rs = 0.99, p = 0.0006). The PVP concentration (median [25th-75th percentiles]) in PS-1.6UW dialyzer washings obtained by rinsing with physiologic saline was 2.0 (1.18-4.85) mg/L with the Müller method and 3.35 (2.38-4.23) mg/L with the UV-s method, showing no significant difference. However, the PVP concentration in APS-15SA dialyzer washings was 0 (0-0.35) mg/L by the Müller method and 0.95 (0.45-2.58) mg/L by the UV-s method, and there was a significant difference between the two methods. In conclusion, the low concentration of PVP eluted from a PSu dialyzer sterilized by gamma radiation was hardly detected by the Müller method but could be clearly detected by the new UV-s method. These findings suggest that the UV-s method could be used for real-time measurement of PVP eluted from PSu membrane dialyzers.

摘要

本研究旨在开发一种测量聚砜(PSu)膜透析器中聚维酮(PVP)洗脱量的新方法。Müller 法通常用于测量 PVP,其中通过向样品中加入碘后形成 PVP-碘络合物,测定其吸光度来确定 PVP 浓度。相比之下,我们的方法不需要任何试剂,并通过紫外吸收光谱(UV-s 法)实现 PVP 的实时测量。在这项研究中,使用 UV-s 法和 Müller 法测量了两种类型的 PSu 膜透析器(通过高压蒸汽灭菌的 PS-1.6UW [n = 10] 和通过γ射线灭菌的 APS-15SA [n = 10])洗脱的 PVP。两种方法测量的 PVP 浓度呈显著正相关(rs = 0.99,p = 0.0006)。用生理盐水冲洗 PS-1.6UW 透析器洗脱液得到的 PVP 浓度(中位数[25% - 75% 分位数]),Müller 法为 2.0(1.18-4.85)mg/L,UV-s 法为 3.35(2.38-4.23)mg/L,差异无统计学意义。然而,APS-15SA 透析器洗脱液中的 PVP 浓度用 Müller 法检测为 0(0-0.35)mg/L,用 UV-s 法检测为 0.95(0.45-2.58)mg/L,两种方法之间存在显著差异。总之,用γ射线灭菌的 PSu 透析器洗脱的 PVP 浓度较低,Müller 法几乎无法检测到,但新的 UV-s 法可以清晰地检测到。这些发现表明,UV-s 法可用于实时测量 PSu 膜透析器中洗脱的 PVP。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验