Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan.
Tokyo Metropolitan Industrial Technology Research Institute, Tokyo, Japan.
J Gastroenterol Hepatol. 2019 Jan;34(1):194-201. doi: 10.1111/jgh.14307. Epub 2018 Jun 28.
Endoscopic ultrasound (EUS)-guided transmural drainage using a covered biflanged metal stent (CBFMS) and a conventional tubular biliary covered self-expandable metal stent (CSEMS) has recently been performed by EUS experts. However, appropriate traction force of the sheath to prevent the migration during stent deployment is well unknown. Herein, we assessed the anchoring force (AF) of the distal flange in CBFMSs and CSEMSs.
The AFs of four CBFMSs (Stents AX, NG, PL, and SX) and six CSEMSs (Stents BF, BP, EG, HN, SP, and WF) were compared in an ex vivo setting. We assessed the AF produced by each stent using an EUS-guided transmural drainage model and an EUS-guided hepaticogastrostomy model consisting of sheet-shaped specimens of the stomach, gelatin gel, and gelatin tubes.
For CBFMSs, the maximum AF of Stent AX was significantly higher than those of Stents PL and SX (P < 0.05) in the porcine model. In the gelatin series, all stents except Stent NG showed a nearly similar AF. For CSEMSs, Stents HN, EG, BF, and WF showed gradual AF elevation in the porcine stomach. Stents SP and BP showed a lower AF than the other four stents. For the gelatin setting, the maximum AF of Stents HN, EG, and WF was higher than those of the other stents regardless of the type of specimens.
The significance of the AF and traction distance according to the property of various CBFMSs and CSEMSs could be elucidated using ex vivo models.
内镜超声(EUS)引导下经壁引流术采用覆盖双凸缘金属支架(CBFMS)和传统管状胆道覆膜自膨式金属支架(CSEMS)已由 EUS 专家开展。然而,对于在支架置放过程中防止支架迁移的鞘管适当牵引力目前尚不清楚。本研究评估了 CBFMS 和 CSEMS 远端凸缘的锚固力(AF)。
在体外环境下,比较了 4 个 CBFMS(Stents AX、NG、PL 和 SX)和 6 个 CSEMS(Stents BF、BP、EG、HN、SP 和 WF)的 AF。我们使用 EUS 引导经壁引流模型和 EUS 引导肝胃吻合模型评估每个支架产生的 AF,模型由胃片状标本、明胶凝胶和明胶管组成。
对于 CBFMS,猪模型中 Stent AX 的最大 AF 明显高于 Stents PL 和 SX(P<0.05)。在明胶系列中,除 Stent NG 外,所有支架的 AF 几乎相似。对于 CSEMS,支架 HN、EG、BF 和 WF 在猪胃中显示出逐渐升高的 AF。支架 SP 和 BP 的 AF 低于其他四个支架。对于明胶设置,支架 HN、EG 和 WF 的最大 AF 高于其他支架,无论标本类型如何。
可以使用体外模型阐明各种 CBFMS 和 CSEMS 性质的 AF 和牵引距离的意义。