Suppr超能文献

犬淋巴瘤全切片成像中的细胞形态学描述及观察者内一致性

Cytomorphological description and intra-observer agreement in whole slide imaging for canine lymphoma.

作者信息

Bonsembiante F, Martini V, Bonfanti U, Casarin G, Trez D, Gelain M E

机构信息

Department of Comparative Biomedicine and Food Science, University of Padua, Viale dell'Università 16, 35020 Legnaro, PD, Italy.

Department of Veterinary Medicine, University of Milan, Via Celoria 10, 20133 Milan, Italy.

出版信息

Vet J. 2018 Jun;236:96-101. doi: 10.1016/j.tvjl.2018.04.020. Epub 2018 May 2.

Abstract

Whole slide imaging (WSI) uses robotic microscopes for computerising entire slides into digital images. The aim of this study was to assess the agreement between WSI and optical microscopy for evaluating canine lymphoma cytological samples. Forty-four slides were computerised using a WSI scanner and the digital and glass slides were examined by three observers with different levels of expertise. Morphology and grade of lymphoma were scored on the basis of the updated Kiel classification and intra-observer agreement was assessed. The accuracy of determining the grade of lymphoma with digital and glass slides based on the results of flow cytometry (FC) was established. The overall intra-observer agreement for cytomorphological features was fair to moderate (κ=0.34-0.52) for the three observers and moderate (κ=0.44-0.53) for the evaluation of grade of malignancy. The diagnostic agreement between FC and digital slides was slight (κ=0.16) for the inexperienced observer, fair (κ=0.32) for the mildly experienced observer and moderate (κ=0.50) for the very experienced observer. The diagnostic agreement between FC and glass slides was fair (κ=0.37) for the inexperienced observer, substantial (κ=0.63) for the mildly experienced observer and moderate (κ=0.50) for the very experienced observer. These findings underline the importance of observer experience in determining the grade of malignancy, especially if digital slides are used. The study also identifies some technical limitations of the WSI scanner used in this study, mainly linked to image quality, which might affect the morphological evaluation of neoplastic cells.

摘要

全玻片成像(WSI)使用机器人显微镜将整个玻片电脑化,转化为数字图像。本研究的目的是评估WSI与光学显微镜在评估犬淋巴瘤细胞学样本方面的一致性。使用WSI扫描仪将44张玻片电脑化,三位具有不同专业水平的观察者对数字玻片和玻璃玻片进行检查。根据更新后的基尔分类对淋巴瘤的形态和分级进行评分,并评估观察者内部的一致性。基于流式细胞术(FC)的结果,确定数字玻片和玻璃玻片在判定淋巴瘤分级方面的准确性。三位观察者在细胞形态学特征方面的总体观察者内部一致性为一般到中等(κ=0.34 - 0.52),在恶性程度分级评估方面为中等(κ=0.44 - 0.53)。对于经验不足的观察者,FC与数字玻片之间的诊断一致性轻微(κ=0.16),对于经验稍丰富的观察者为一般(κ=0.32),对于经验丰富的观察者为中等(κ=0.50)。对于经验不足的观察者,FC与玻璃玻片之间的诊断一致性为一般(κ=0.37),对于经验稍丰富的观察者为显著(κ=0.63),对于经验丰富的观察者为中等(κ=0.50)。这些发现强调了观察者经验在判定恶性程度分级中的重要性,特别是在使用数字玻片时。该研究还指出了本研究中使用的WSI扫描仪的一些技术局限性,主要与图像质量有关,这可能会影响肿瘤细胞的形态学评估。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验