Suppr超能文献

利用体内红细胞标记和动态闪烁扫描术测量小鼠肿瘤的血液供应。

Measurement of blood supply to murine tumours using in vivo red cell labelling and dynamic scintigraphy.

作者信息

Baker G M, Clarke M B, Whimster W F

出版信息

Br J Cancer. 1985 Jun;51(6):783-9. doi: 10.1038/bjc.1985.122.

Abstract

Blood pool and flow were studied in transplanted adenocarcinomas on the legs of mice. The animals' red blood cells were labelled in vivo by consecutive injections of a stannous compound and 99mTc-pertechnetate. The distribution of radioactivity was then recorded continuously with a gamma camera. This method allows prolonged and repeated estimations of blood supply to undisturbed tumours in conscious mice. It was found that in small tumours (under 1 ml) circulating blood pool was usually high, often 2 or 3 times that in normal leg tissues. In tumours bigger than 1 ml blood pool per unit volume tended to be lower but was still about 1.5 times the normal tissue level. This relatively large blood volume would seem to be outweighed by a very slow rate of flow. Even in the small tumours blood perfusion was greatly reduced compared to that in the normal leg. The blood pool results here provide no evidence that in tumours larger than 1 ml blood supply decreased progressively with growth.

摘要

对小鼠腿部移植的腺癌中的血池和血流进行了研究。通过连续注射一种亚锡化合物和高锝[99mTc]酸盐,在体内标记动物的红细胞。然后用γ相机连续记录放射性分布。该方法可以对清醒小鼠未受干扰的肿瘤的血液供应进行长时间和重复的评估。研究发现,在小肿瘤(体积小于1毫升)中,循环血池通常较高,常常是正常腿部组织的2至3倍。在体积大于1毫升的肿瘤中,单位体积的血池往往较低,但仍约为正常组织水平的1.5倍。这种相对较大的血容量似乎被非常缓慢的血流速度所抵消。即使在小肿瘤中,与正常腿部相比,血液灌注也大大减少。这里的血池结果没有提供证据表明,体积大于1毫升的肿瘤的血液供应会随着生长而逐渐减少。