Effect of Cardiogenic Oscillations on Trigger Delay During Pressure Support Ventilation.

作者信息

Plens Glauco M, Morais Caio Ca, Nakamura Maria A, Souza Patricia N, Amato Marcelo Bp, Tucci Mauro R, Costa Eduardo Lv

机构信息

Divisao de Pneumologia, Instituto do Coracao, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, Brazil.

Hospital Sírio Libanês, São Paulo, Brazil.

出版信息

Respir Care. 2018 Jul;63(7):865-872. doi: 10.4187/respcare.05995. Epub 2018 Jun 12.

DOI:10.4187/respcare.05995
PMID:29895701
Abstract

BACKGROUND

Sensitive flow or pressure triggers are usually applied to improve ventilator response time. Conversely, too sensitive triggers can incur risk of auto-triggering, a type of asynchrony in which a breath is triggered without inspiratory muscle activity. A frequent cause of auto-triggering is cardiogenic oscillations, characterized by cyclical variations in pressure and flow waveforms caused by cardiac contractions. Our goal was to test trigger performance and capacity to abolish auto-triggering in 5 different ICU ventilators using different simulated levels of cardiogenic oscillations.

METHODS

A mechanical breathing simulator was used to test 5 different ICU ventilators' trigger response time and capacity to minimize auto-triggering in conditions with 0, 0.25, 0.5, and 1 cm HO cardiogenic oscillation. Each ventilator was evaluated until an ideal trigger was found (the most sensitive that abolished auto-triggering). When the least sensitive flow trigger was unable to avoid auto-triggering, a pressure trigger was used. We compared time delay, airway pressure drop until triggering, and work of breathing before each trigger, all at the ideal trigger level for each cardiogenic oscillation amplitude. We also assessed the proportion of auto-triggered breaths in the whole range of trigger levels tested.

RESULTS

Larger cardiogenic oscillations were associated with more frequent auto-triggering. To avoid auto-triggering, less sensitive triggers were required (+2.51 L/min per 1 cm HO increase in cardiogenic oscillation; 95% CI 2.26-2.76, < .001). Time delay increased with larger cardiogenic oscillations, because less sensitive trigger levels were required to abolish auto-triggering (4.79-ms increase per 1 L/min increment on flow trigger).

CONCLUSIONS

More sensitive triggers led to faster ventilator response, but also to more frequent auto-triggering. To avoid auto-triggering, less sensitive triggers were required, with consequent slower trigger response. To compare trigger performance in a scenario that more closely represents clinical practice, evaluation of the tradeoff between time delay and frequency of auto-triggering should be considered.

摘要

相似文献

1
Effect of Cardiogenic Oscillations on Trigger Delay During Pressure Support Ventilation.
Respir Care. 2018 Jul;63(7):865-872. doi: 10.4187/respcare.05995. Epub 2018 Jun 12.
2
Autotriggering caused by cardiogenic oscillation during flow-triggered mechanical ventilation.流量触发机械通气期间心源性振荡引起的自动触发。
Crit Care Med. 2000 Feb;28(2):402-7. doi: 10.1097/00003246-200002000-00019.
3
Neurally triggered breaths have reduced response time, work of breathing, and asynchrony compared with pneumatically triggered breaths in a recovering animal model of lung injury.与气动触发呼吸相比,神经触发呼吸可减少呼吸反应时间、呼吸功和不同步性,这在肺损伤的动物模型恢复期得到了验证。
Pediatr Crit Care Med. 2012 May;13(3):e195-203. doi: 10.1097/PCC.0b013e318238b40d.
4
Effects of different triggering systems and external PEEP on trigger capability of the ventilator.不同触发系统和外部呼气末正压对呼吸机触发能力的影响。
Intensive Care Med. 1996 Apr;22(4):363-8. doi: 10.1007/BF01700461.
5
Influences of Duration of Inspiratory Effort, Respiratory Mechanics, and Ventilator Type on Asynchrony With Pressure Support and Proportional Assist Ventilation.吸气努力持续时间、呼吸力学和通气机类型对压力支持通气和比例辅助通气不同步的影响
Respir Care. 2017 May;62(5):550-557. doi: 10.4187/respcare.05025. Epub 2017 Feb 14.
6
Performance of transport ventilator with patient-triggered ventilation.具备患者触发通气功能的转运呼吸机的性能
Chest. 2000 Oct;118(4):1109-15. doi: 10.1378/chest.118.4.1109.
7
Using tracheal pressure to trigger the ventilator and control airway pressure during continuous positive airway pressure decreases work of breathing.在持续气道正压通气期间,利用气管压力触发呼吸机并控制气道压力可降低呼吸功。
Chest. 1995 Aug;108(2):509-14. doi: 10.1378/chest.108.2.509.
8
Performance characteristics of seven bilevel mechanical ventilators in pressure-support mode with different cycling criteria: a comparative bench study.七种双水平机械通气机在不同切换标准的压力支持模式下的性能特征:一项对比性实验台研究
Med Sci Monit. 2015 Jan 26;21:310-7. doi: 10.12659/MSM.892080.
9
[A comparison of leak compensation in six acute care ventilators during non-invasive ventilation].[六种急性护理呼吸机在无创通气期间的漏气补偿比较]
Zhonghua Jie He He Hu Xi Za Zhi. 2017 Feb 12;40(2):90-97. doi: 10.3760/cma.j.issn.1001-0939.2017.02.003.
10
Effects of the flow waveform method of triggering and cycling on patient-ventilator interaction during pressure support.压力支持期间触发和切换的流量波形方法对患者-呼吸机相互作用的影响。
Intensive Care Med. 2003 Nov;29(11):1950-9. doi: 10.1007/s00134-003-1703-5. Epub 2003 Mar 29.