Department of Public Health & Pediatrics, University of Torino, via Santena 9, Turin 10126, Italy.
Department of Orthopedics & Traumatology, AOU Città della Scienza e della Salute, CTO Hospital, via Zuretti 29, Turin 10126, Italy.
Future Microbiol. 2018 Sep;13:1295-1299. doi: 10.2217/fmb-2018-0135. Epub 2018 Jun 18.
Prosthetic joint infection diagnosis is often difficult since biofilm-embedded microorganisms attach well to the prosthetic surfaces and resist their detection by conventional methods. DL-dithiothreitol has been described as a valid method for biofilm detachment on orthopedic devices. We report the case of an occasional detection of Listeria monocytogenes in a non immuno-compromised patient with a preoperative diagnosis of aseptic loosening. The infection diagnosis due to such rare bacteria was made postoperatively, thanks to a DL-dithiothreitol-based device. This may be considered a feasible approach for the microbiological analysis of prosthetic joint infection, considering that a prompt diagnosis of such biofilm-associated infections could bring some advantages, such as an early and appropriate antibiotic therapy administration and a reduction of undiagnosed infections.
人工关节感染的诊断通常较为困难,因为生物膜包裹的微生物与假体表面紧密结合,常规方法难以检测到。DL-二硫苏糖醇已被描述为一种有效的去除骨科器械生物膜的方法。我们报告了一例非免疫功能低下的患者,术前诊断为无菌性松动,偶然在术后检测到单核细胞增生李斯特菌。由于这种罕见的细菌,感染诊断是在术后进行的,这要归功于一种基于 DL-二硫苏糖醇的设备。考虑到这种生物膜相关感染的快速诊断可能带来一些优势,例如早期和适当的抗生素治疗以及减少未确诊的感染,这种方法可能被认为是一种可行的人工关节感染微生物分析方法。