Suppr超能文献

成功的人工晶状体植入术:4例病例的组织学和扫描电子显微镜研究

Successful intraocular lens implantation: a histological and scanning electron microscopic study of four cases.

作者信息

Mullaney J, Lucas D R, Condon P I

出版信息

Acta Ophthalmol Suppl (1985). 1985;170:41-9. doi: 10.1111/j.1755-3768.1985.tb05259.x.

Abstract

The histological findings in four globes obtained at autopsy from clinically uncomplicated cases with intraocular lens implants, one glass posterior chamber and three anterior chamber lenses consisting of two pupillary fixated and one "in-the-bag" fixated Binkhorst lens, are reported. Minimal changes could be detected in the tissues with which the implants were in contact. Scanning electron microscopy of the cornea in the three anterior chamber implants showed a loss of endothelial cells in the axial region of roughly 30-50%. There was marked vertical disparity in the loss. Scanning microscopy of the implants showed evidence of surface degradation of the nylon loops of all the anterior chamber implants.

摘要

报告了从临床无并发症的人工晶状体植入病例尸检获得的四个眼球的组织学结果,其中一个为玻璃后房型人工晶状体,三个为前房型人工晶状体,包括两个瞳孔固定型和一个囊袋内固定型宾克霍斯特人工晶状体。在与植入物接触的组织中可检测到微小变化。对三个前房型植入物的角膜进行扫描电子显微镜检查显示,轴向区域内皮细胞损失约30%-50%。损失存在明显的垂直差异。对植入物进行扫描显微镜检查显示,所有前房型植入物的尼龙袢表面均有降解迹象。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验