Suppr超能文献

EXOSEAL血管闭合装置在腘动脉入路中的应用

Implementation of the EXOSEAL Vascular Closure Device in the Transpopliteal Arterial Approach.

作者信息

Ballı Ömür, Çakır Volkan, Coşkun Mehmet, Pekçevik Rıdvan, Gür Serkan

机构信息

Department of Interventional Radiology, İzmir Katip Çelebi University Atatürk Training and Research Hospital, İzmir TR 35360, Turkey.

Department of Interventional Radiology, İzmir Katip Çelebi University Atatürk Training and Research Hospital, İzmir TR 35360, Turkey.

出版信息

J Vasc Interv Radiol. 2018 Aug;29(8):1180-1186. doi: 10.1016/j.jvir.2018.03.023. Epub 2018 Jun 21.

Abstract

PURPOSE

To investigate the feasibility and safety of the EXOSEAL vascular closure device (VCD) in achieving hemostasis in transpopliteal arterial interventions.

MATERIALS AND METHODS

Between May 2014 and May 2016, 46 procedures involving transpopliteal arterial access in 28 patients (18 bilateral and 10 unilateral) were analyzed retrospectively. Popliteal arterial puncture was performed under ultrasonographic (US) and fluoroscopic guidance by using a micropuncture access set with a 21-gauge needle. Six-French sheaths were used in 45 procedures, and a 7-F sheath was used in 1 procedure. Hemostasis was achieved with the EXOSEAL VCD. All patients were examined for any access-related complications with US at 6 and 24 hours after the procedure. One week later, all patients were followed up in the outpatient clinic.

RESULTS

In 44 of the 46 procedures, the EXOSEAL VCD was applied successfully. The technical failure rate was 4.4%. An excessively steep angle of the introducer sheath and improper placement of the EXOSEAL plug in the setting of high blood pressure (220/120 mm Hg) were the reasons for the 2 failures. Among the 44 successful procedures, 1 (2.3%) minor 3-cm hematoma was found to be associated with the VCD. In 1 of the 46 procedures, an arteriovenous fistula (2.2%) was observed as a puncture-related complication and treated with a stent graft.

CONCLUSIONS

The EXOSEAL VCD can be safely used for hemostasis in interventions that use transpopliteal arterial approaches, with a high technical success rate and a low rate of entry-site complications.

摘要

目的

探讨EXOSEAL血管闭合装置(VCD)在腘动脉介入治疗中实现止血的可行性和安全性。

材料与方法

回顾性分析2014年5月至2016年5月期间28例患者(18例双侧和10例单侧)的46例涉及腘动脉穿刺的手术。在超声(US)和荧光透视引导下,使用带21号针头的微穿刺套件进行腘动脉穿刺。45例手术使用6F鞘,1例手术使用7F鞘。采用EXOSEAL VCD实现止血。术后6小时和24小时对所有患者进行超声检查,以排查任何与穿刺相关的并发症。一周后,所有患者在门诊进行随访。

结果

46例手术中的44例成功应用了EXOSEAL VCD。技术失败率为4.4%。2例失败的原因是导入鞘角度过大以及在高血压(220/120 mmHg)情况下EXOSEAL封堵器放置不当。在44例成功手术中,发现1例(2.3%)3 cm小血肿与VCD有关。46例手术中有1例(2.2%)观察到动静脉瘘为穿刺相关并发症,并采用覆膜支架进行治疗。

结论

EXOSEAL VCD可安全用于腘动脉入路的介入治疗止血,技术成功率高,穿刺部位并发症发生率低。