Huang S K, Wang J, Li Y, Lin H, Li D D, Cui C J, Wang G J, Li X X, Yang L, Zhao M, Huang C Z
Department of Clinical Laboratory, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China.
Department of Clinical Laboratory, China Meitan General Hospital, Beijing 100028, China.
Zhonghua Zhong Liu Za Zhi. 2018 Jun 23;40(6):441-445. doi: 10.3760/cma.j.issn.0253-3766.2018.06.008.
To investigate the clinical value of combined detection of serum miR-378 and miR-21 in gastric cancer (GC). Eighty-seven patients with GC and 78 patients with colorectal cancer(CRC) from National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences were selected, 83 individuals undergoing healthy physical examination were selected as the healthy controls. The levels of serum miR-378 and miR-21 were detected by quantitative real-time PCR (RT-qPCR) (result data were transformed as log2 for analysis). Relative expression levels of miR-378 in the serum were -1.24, -3.25 and -2.73 in healthy controls, GC and CRC patients, respectively. Compared with the healthy controls, the levels of serum miR-378 were significantly decreased in GC and CRC patients (both <0.05). Relative expression levels of miR-21 in the serum were 0.11, 2.34 and 2.47 in healthy controls, GC and CRC patients, respectively. Compared with the healthy controls, the levels of serum miR-21 were significantly up-regulated in GC and CRC patients (both <0.05). Moreover, the serum level of miR-378 in GC patients was inversely associated with tumor clinical stage (<0.05). However, the level of miR-21 showed no significant differences among patients with different clinical and pathological characteristics (all >0.05). The area under the receiver operating characteristic curve (AUC), sensitivity and specificity of miRNA-378 to diagnose GC was 0.770, 82.0% and 66.0%, respectively, and were 0.900, 85.0%, and 88.0% of miR-21, respectively. The AUC, sensitivity and specificity of combined detection of serum miR-378 and miR-21 to diagnose GC were 0.930, 92.0% and 87.0%, respectively, while the AUC of combined detection of serum CEA and CA-199 was 0.767, the AUC of combined all of the four factors was 0.946. The combined detection of serum miR-378 and miR-21 have a certain effect on diagnosis of GC.
探讨血清miR-378和miR-21联合检测在胃癌(GC)中的临床价值。选取中国医学科学院肿瘤医院国家癌症中心的87例GC患者和78例结直肠癌(CRC)患者,选取83例进行健康体检的个体作为健康对照。采用定量实时荧光定量PCR(RT-qPCR)检测血清miR-378和miR-21水平(结果数据转化为log2进行分析)。健康对照、GC患者和CRC患者血清中miR-378的相对表达水平分别为-1.24、-3.25和-2.73。与健康对照相比,GC患者和CRC患者血清miR-378水平显著降低(均P<0.05)。健康对照、GC患者和CRC患者血清中miR-21的相对表达水平分别为0.11、2.34和2.47。与健康对照相比,GC患者和CRC患者血清miR-21水平显著上调(均P<0.05)。此外,GC患者血清miR-378水平与肿瘤临床分期呈负相关(P<0.05)。然而,miR-21水平在不同临床病理特征的患者中无显著差异(均P>0.05)。miRNA-378诊断GC的受试者工作特征曲线(AUC)下面积、敏感性和特异性分别为0.770、82.0%和66.0%,miR-21的分别为0.900、85.0%和88.0%。血清miR-378和miR-21联合检测诊断GC的AUC、敏感性和特异性分别为0.930、92.0%和87.0%,而血清癌胚抗原(CEA)和糖类抗原199(CA-199)联合检测的AUC为0.767,四项指标联合检测的AUC为0.946。血清miR-378和miR-21联合检测对GC诊断有一定作用。