Interobserver reliability of sonographic fetal biometry in second trimester maternal serum screening.

作者信息

Aksoy H, Ozyurt S, Aksoy U, Ozdamar O, Mutlu E, Tutus S, Babayigit M A, Acmaz G

出版信息

Clin Exp Obstet Gynecol. 2017;44(3):379-383.

Abstract

PURPOSE

To examine the interobserver variability for fetal biometry parameters and to investigate whether this variability affects the second-trimester maternal serum screening test (STMSS) results.

MATERIALS AND METHODS

A total of 60 singleton pregnancies who were scheduled for STMSS were investigated. Two experienced sonographers performed all examinations at the same visit. The risk calclations of screening were performed according to the each operator's biometric measurements separately. Interobserver variability in measurements of fetal biometrics and the effect of this interobserver variability on the screening results were assessed.

RESULTS

inter-observer reliability for biparietal diameter (BPD) and femur length (FL) were 0.904 and 0.888 (p < 0.00 1), respectively. interobserver reliability coefficients for trisomy 21, trisomy 13/18, and neural tube defect were 0.887, 0.999, and 0.920 (p < 0.0001), respectively.

CONCLUSION

The present results demonstrate that the interobserver reliability and agreement of ultrasound measurements of fetal biometry in cases of routine prenatal screening are highly reliable.

摘要

目的

研究胎儿生物测量参数的观察者间变异性,并探讨这种变异性是否会影响孕中期母血清筛查试验(STMSS)结果。

材料与方法

共调查了60例计划进行STMSS的单胎妊娠。两名经验丰富的超声检查医师在同一次检查中完成所有检查。分别根据每位操作者的生物测量数据进行筛查风险计算。评估了胎儿生物测量的观察者间变异性以及这种观察者间变异性对筛查结果的影响。

结果

双顶径(BPD)和股骨长度(FL)的观察者间可靠性分别为0.904和0.888(p<0.001)。21三体、13/18三体和神经管缺陷的观察者间可靠性系数分别为0.887、0.999和0.920(p<0.0001)。

结论

目前的结果表明,在常规产前筛查中,胎儿生物测量超声测量的观察者间可靠性和一致性是高度可靠的。