Suppr超能文献

用矢量血流成像和多普勒超声估计股总静脉峰值速度的呼吸变异性。

Respiratory variability of peak velocities in the common femoral vein estimated with vector flow imaging and Doppler ultrasound.

作者信息

Bechsgaard Thor, Hansen Kristoffer Lindskov, Brandt Andreas Hjelm, Moshavegh Ramin, Forman Julie Lyng, Føgh Pia, Klitfod Lotte, Bækgaard Niels, Lönn Lars, Nielsen Michael Bachmann, Jensen Jørgen Arendt

机构信息

Department of Diagnostic Radiology, Rigshospitalet - Copenhagen University Hospital, Copenhagen Ø, Denmark.

Department of Diagnostic Radiology, Rigshospitalet - Copenhagen University Hospital, Copenhagen Ø, Denmark.

出版信息

Ultrasound Med Biol. 2018 Sep;44(9):1941-1950. doi: 10.1016/j.ultrasmedbio.2018.05.006. Epub 2018 Jun 28.

Abstract

Respiratory variability of peak velocities (RVPV) in the common femoral vein measured with ultrasound can reveal venous outflow obstruction. Pulse wave (PW) Doppler is the gold standard for venous velocity estimation of the lower extremities. PW Doppler measurements are angle dependent, whereas vector flow imaging (VFI) can yield angle-independent measures. The hypothesis of the present study was that VFI can provide RVPV estimations without the angle dependency of PW Doppler for an improved venous disease assessment. Sixty-seven patients with symptomatic chronic venous disease were included in the study. On average, VFI measured a lower RVPV than PW Doppler (VFI: 14.11 cm/s; PW: 17.32 cm/s, p = 0.002) with a non-significant improved precision compared with PW Doppler (VFI: 21.09%; PW: 26.49%, p = 0.08). In a flow phantom, VFI had improved accuracy (p < 0.01) and equal precision compared with PW Doppler. The study indicated that VFI can characterize the hemodynamic fluctuations in the common femoral vein.

摘要

用超声测量的股总静脉峰值速度的呼吸变异性(RVPV)可揭示静脉流出道梗阻。脉冲波(PW)多普勒是下肢静脉速度估计的金标准。PW多普勒测量依赖角度,而向量血流成像(VFI)可产生与角度无关的测量值。本研究的假设是,VFI可以提供RVPV估计值,而不存在PW多普勒的角度依赖性,从而改善静脉疾病评估。67例有症状的慢性静脉疾病患者纳入本研究。平均而言,VFI测量的RVPV低于PW多普勒(VFI:14.11 cm/s;PW:17.32 cm/s,p = 0.002),与PW多普勒相比,精度提高不显著(VFI:21.09%;PW:26.49%,p = 0.08)。在血流模型中,与PW多普勒相比,VFI具有更高的准确性(p < 0.01)和相同的精度。该研究表明,VFI可以表征股总静脉的血流动力学波动。