Department of Surgery (Otolaryngology) University of Melbourne.
Royal Victorian Eye and Ear Hospital, Melbourne, Australia.
Otol Neurotol. 2018 Aug;39(7):e524-e531. doi: 10.1097/MAO.0000000000001840.
To use video head impulse testing to examine the effect of cochlear implantation (CI) on horizontal SCC vestibulo-ocular reflex (VOR) gain early after surgery, and to relate outcomes to subjective imbalance.
Prospective cohort study.
Academic tertiary referral center.
Thirty-seven (23F:14M) adult cochlear implant recipients (mean age, 55; age range, 20-80).
Cochlear implantation.
The VOR of the horizontal semicircular canal of both the operated and non-operated ears was examined using video head impulse testing before surgery and at days 1, 7, and 28 following surgery. VOR gain, VOR gain asymmetry, and the change in VOR gain from preoperative baseline where the primary outcome measures. Subjective imbalance was assessed using a structured questionnaire.
VOR gain value for the operated ear was 0.88 ± 0.21. Mean VOR gain on day 1 postoperatively was 0.86 ± 0.19; on day 7, 0.87 ± 0.17, and on day 30, 0.91 ± 0.21. Before surgery median asymmery was -5.50%, on day 1 it was -5.30%, at day 7, -6.44%, and at day 30 it was -2.61%. There was no significant difference between these measures for the cohort across the four time points. Thirteen of 37 (35%) of patients experienced imbalance in the follow-up period, but this was not correlated to changes in VOR gain.
Horizontal semicircular canal function is preserved in the immediate and early postoperative period. This suggests that horizontal semicircular canal impairment is not likely to be responsible for postoperative imbalance.
使用视频头脉冲测试检查耳蜗植入(CI)手术后早期对水平 SCC 前庭眼反射(VOR)增益的影响,并将结果与主观失衡相关联。
前瞻性队列研究。
学术三级转诊中心。
37 名(23F:14M)成年耳蜗植入受者(平均年龄 55 岁;年龄范围 20-80 岁)。
耳蜗植入。
手术前和手术后第 1、7 和 28 天,使用视频头脉冲测试检查双侧水平半规管的 VOR。VOR 增益、VOR 增益不对称和 VOR 增益从术前基线的变化是主要的观察指标。使用结构化问卷评估主观失衡。
手术耳的 VOR 增益值为 0.88±0.21。术后第 1 天的平均 VOR 增益为 0.86±0.19;第 7 天为 0.87±0.17,第 30 天为 0.91±0.21。术前中位数不对称为-5.50%,第 1 天为-5.30%,第 7 天为-6.44%,第 30 天为-2.61%。在四个时间点,整个队列的这些测量值之间没有显著差异。在随访期间,13 名(35%)患者出现失衡,但这与 VOR 增益的变化无关。
水平半规管功能在术后即刻和早期得到保留。这表明水平半规管损伤不太可能是术后失衡的原因。