肿瘤与颈椎标准化摄取值比(SUR)提高了多中心环境下基于 F-FDG-PET 的头颈部鳞状细胞癌肿瘤分割的可重复性。

Tumor to cervical spinal cord standardized uptake ratio (SUR) improves the reproducibility of F-FDG-PET based tumor segmentation in head and neck squamous cell carcinoma in a multicenter setting.

机构信息

Department of Radiation Oncology, Radboud University Medical Center, Nijmegen, The Netherlands.

Department of Radiation Oncology, Radboud University Medical Center, Nijmegen, The Netherlands.

出版信息

Radiother Oncol. 2019 Jan;130:39-45. doi: 10.1016/j.radonc.2018.06.037. Epub 2018 Jul 10.

Abstract

BACKGROUND

In quantitative FDG-PET data analysis, normalization of the standardized uptake value (SUV) with an internal image-derived standard improves its reproducibility. In this study, the cervical spinal cord is proposed as an internal standard that is within the field of view of the radiotherapy planning PET/CT-scan in head and neck cancer. The aim is to evaluate if the tumor to cervical spinal cord standardized uptake ratio (SUR) can improve the reproducibility of a model to determine the metabolic tumor volume (MTV) on FDG-PET/CT in a multicenter setting.

MATERIALS AND METHODS

Ninety-five radiotherapy planning FDG-PET/CT-scans of patients with head and neck cancer were analyzed using the Bland-Altman method to evaluate differences in FDG-uptake in the cervical spinal cord and the mediastinal blood pool. Non-linear regression analysis was used to determine the optimal MTV using the gross tumor volume (GTV) as ground truth and a spatial overlap-index as statistical validation metric. Reproducibility was evaluated using the Bland-Altman method and external validation was performed in an independent dataset consisting of 62 patients.

RESULTS

Bland-Altman's analyses demonstrated equivalence of FDG-uptake in the mediastinal blood pool and the cervical spinal cord. Reproducibility of the models improved when using SUR instead of SUV. These results were confirmed in the validation cohort.

CONCLUSION

The use of the tumor to cervical spinal cord SUR instead of SUV improves the reproducibility of a model to determine the MTV on FDG-PET/CT in a multicenter setting. This study indicates that SUR may be preferred over SUV based approaches.

摘要

背景

在定量 FDG-PET 数据分析中,通过内部图像衍生标准对标准化摄取值(SUV)进行归一化可以提高其可重复性。在这项研究中,颈椎被提议作为头颈部癌症放射治疗计划 PET/CT 扫描视野内的内部标准。目的是评估肿瘤与颈椎的标准化摄取比值(SUR)是否可以提高在多中心环境下使用 FDG-PET/CT 确定代谢肿瘤体积(MTV)的模型的可重复性。

材料和方法

分析了 95 例头颈部癌症患者的放射治疗计划 FDG-PET/CT 扫描,使用 Bland-Altman 方法评估了颈椎和纵隔血池中的 FDG 摄取差异。使用非线性回归分析,以肿瘤总体积(GTV)作为真实值,并使用空间重叠指数作为统计验证指标,确定最佳 MTV。使用 Bland-Altman 方法评估了可重复性,并在由 62 例患者组成的独立数据集上进行了外部验证。

结果

Bland-Altman 分析表明纵隔血池和颈椎中的 FDG 摄取等效。当使用 SUR 代替 SUV 时,模型的可重复性提高。这些结果在验证队列中得到了证实。

结论

在多中心环境下,使用肿瘤与颈椎的 SUR 代替 SUV 可以提高 FDG-PET/CT 上确定 MTV 的模型的可重复性。本研究表明,SUR 可能优于基于 SUV 的方法。