Suppr超能文献

间歇性外斜视患者的双眼对比敏感度异常相加。

Subnormal Binocular Contrast Sensitivity Summation in Patients with Intermittent Exotropia.

机构信息

Department of Ophthalmology, Pusan National University School of Medicine, Yangsan, Korea.

Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea.

出版信息

J Korean Med Sci. 2018 Jul 5;33(32):e222. doi: 10.3346/jkms.2018.33.e222. eCollection 2018 Aug 6.

Abstract

BACKGROUND

To evaluate binocular summation ratio using contrast sensitivity (CS) testing and correlation between binocular summation and stereoacuity, and control scale in intermittent exotropia (IXT).

METHODS

We conducted a prospective case-control study. Thirty-seven IXT and 41 controls were evaluated with both monocular and binocular CS testing. We compared the binocular summation ratio of IXT to that of controls. Near and distance stereoacuity was assessed and office-based control scale was evaluated. We investigated correlation between binocular CS summation ratio and stereoacuity, and control scale in IXT, respectively.

RESULTS

IXT had lower binocular CS summation ratio than controls at 1.5 and 3.0 cycles/degree (1.01 ± 1.02 vs. 1.62 ± 1.88 and 1.17 ± 0.96 vs. 1.86 ± 1.75, Both < 0.05). We found significant correlation between binocular CS summation ratio at 3.0 cycles/degree and both near and distance stereoacuity ( = -0.411, = 0.012 and = -0.624, = 0.005), and ratio at 1.5 cycles/degree also correlated significantly with distance stereoacuity ( = -0.397, = 0.034) in the IXT. Binocular CS summation ratio was correlated to control scale at 1.5 and 3.0 cycles/degree ( = -0.327, = 0.041 and = -0.418, = 0.028), and the ratio significantly differed in control scale groupings analysis at the same frequencies (Both < 0.05).

CONCLUSION

Our findings of subnormal binocular CS summation ratio in IXT had correlation with stereoacuity and control scale suggest that binocular CS testing may be a useful method in assessing binocular visual function in IXT.

摘要

背景

评估双眼总和比使用对比敏感度 (CS) 测试和双眼总和与立体视锐度之间的相关性,并控制间歇性外斜视 (IXT) 的标度。

方法

我们进行了一项前瞻性病例对照研究。37 例 IXT 和 41 例对照者均进行了单眼和双眼 CS 测试。我们比较了 IXT 的双眼总和比与对照组的双眼总和比。评估近距和远距立体视锐度,并进行基于办公室的控制量表评估。我们分别研究了 IXT 中双眼 CS 总和比与立体视锐度和控制量表之间的相关性。

结果

IXT 的双眼 CS 总和比在 1.5 和 3.0 周期/度时低于对照组(1.01 ± 1.02 对 1.62 ± 1.88 和 1.17 ± 0.96 对 1.86 ± 1.75,均 < 0.05)。我们发现,3.0 周期/度的双眼 CS 总和比与近距和远距立体视锐度显著相关( = -0.411, = 0.012 和 = -0.624, = 0.005),而 1.5 周期/度的比值也与 IXT 中的远距立体视锐度显著相关( = -0.397, = 0.034)。在 IXT 中,1.5 和 3.0 周期/度的双眼 CS 总和比与控制量表相关( = -0.327, = 0.041 和 = -0.418, = 0.028),在相同频率的控制量表分组分析中,比值差异显著(均 < 0.05)。

结论

我们发现 IXT 中双眼 CS 总和比异常与立体视锐度和控制量表相关,表明双眼 CS 测试可能是评估 IXT 双眼视觉功能的一种有用方法。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6992/6070470/f69000dbee1f/jkms-33-e222-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验