To evaluate binocular summation ratio using contrast sensitivity (CS) testing and correlation between binocular summation and stereoacuity, and control scale in intermittent exotropia (IXT).
We conducted a prospective case-control study. Thirty-seven IXT and 41 controls were evaluated with both monocular and binocular CS testing. We compared the binocular summation ratio of IXT to that of controls. Near and distance stereoacuity was assessed and office-based control scale was evaluated. We investigated correlation between binocular CS summation ratio and stereoacuity, and control scale in IXT, respectively.
IXT had lower binocular CS summation ratio than controls at 1.5 and 3.0 cycles/degree (1.01 ± 1.02 vs. 1.62 ± 1.88 and 1.17 ± 0.96 vs. 1.86 ± 1.75, Both < 0.05). We found significant correlation between binocular CS summation ratio at 3.0 cycles/degree and both near and distance stereoacuity ( = -0.411, = 0.012 and = -0.624, = 0.005), and ratio at 1.5 cycles/degree also correlated significantly with distance stereoacuity ( = -0.397, = 0.034) in the IXT. Binocular CS summation ratio was correlated to control scale at 1.5 and 3.0 cycles/degree ( = -0.327, = 0.041 and = -0.418, = 0.028), and the ratio significantly differed in control scale groupings analysis at the same frequencies (Both < 0.05).
Our findings of subnormal binocular CS summation ratio in IXT had correlation with stereoacuity and control scale suggest that binocular CS testing may be a useful method in assessing binocular visual function in IXT.
评估双眼总和比使用对比敏感度 (CS) 测试和双眼总和与立体视锐度之间的相关性,并控制间歇性外斜视 (IXT) 的标度。
我们进行了一项前瞻性病例对照研究。37 例 IXT 和 41 例对照者均进行了单眼和双眼 CS 测试。我们比较了 IXT 的双眼总和比与对照组的双眼总和比。评估近距和远距立体视锐度,并进行基于办公室的控制量表评估。我们分别研究了 IXT 中双眼 CS 总和比与立体视锐度和控制量表之间的相关性。
IXT 的双眼 CS 总和比在 1.5 和 3.0 周期/度时低于对照组(1.01 ± 1.02 对 1.62 ± 1.88 和 1.17 ± 0.96 对 1.86 ± 1.75,均 < 0.05)。我们发现,3.0 周期/度的双眼 CS 总和比与近距和远距立体视锐度显著相关( = -0.411, = 0.012 和 = -0.624, = 0.005),而 1.5 周期/度的比值也与 IXT 中的远距立体视锐度显著相关( = -0.397, = 0.034)。在 IXT 中,1.5 和 3.0 周期/度的双眼 CS 总和比与控制量表相关( = -0.327, = 0.041 和 = -0.418, = 0.028),在相同频率的控制量表分组分析中,比值差异显著(均 < 0.05)。
我们发现 IXT 中双眼 CS 总和比异常与立体视锐度和控制量表相关,表明双眼 CS 测试可能是评估 IXT 双眼视觉功能的一种有用方法。