Suppr超能文献

对比增强超声与正电子发射断层扫描/计算机断层扫描(PET/CT)在淋巴瘤中的比较。

Comparison of Contrast-Enhanced Ultrasound and Positron Emission Tomography/Computed Tomography (PET/CT) in Lymphoma.

机构信息

Department of Ultrasound, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, China (mainland).

Department of Lymphoma, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, China (mainland).

出版信息

Med Sci Monit. 2018 Aug 10;24:5558-5565. doi: 10.12659/MSM.908849.

Abstract

BACKGROUND This study aimed to assess the value of contrast-enhanced ultrasound (CEUS) in the diagnosis and prognosis of lymphoma based on PET-CT. MATERIAL AND METHODS Our study included 88 superficial lymph nodes and 63 patients who underwent ultrasound-guided biopsy or surgery for pathology from October 2015 to March 2017. All lymph nodes were assessed by CEUS and PET-CT. CEUS and PET-CT parameters were recorded, including arrive time (AT), time to peak (TTP), base intensity (BI), peak intensity (PI), ascending slope (AS), descending slope (DS), area under the TIC curve (AUC), maximum standardized uptake value (SUVmax), and mean standardized uptake value (SUVmean). Pearson's correlation was used to assess the associations of CEUS and PET-CT parameters. RESULTS Of the 88 lymph nodes examined,12 were Hodgkin's lymphoma (HL) and76 were non-Hodgkin's lymphoma (NHL). The variations of CEUS dose parameters (ΔI, AUC, and AS) were positively correlated with PET-CT results (SUVmax and TLG). Correlation coefficients were 0.609, 0.518, 0.456, 0.630, 0.593, and 0. 532, respectively. The remaining time values (AT, TP, and ΔT) were negatively associated with PET-CT results. Correlation coefficients were -0.239, -0.272, -0.284and -0.377, -0.391, and -0.320, respectively. CONCLUSIONS Quantitative CEUS data were correlated with PET-CT values, with potential use in the diagnosis of lymphoma.

摘要

背景 本研究旨在评估基于 PET-CT 的对比增强超声(CEUS)在淋巴瘤诊断和预后中的价值。

材料与方法 本研究纳入了 2015 年 10 月至 2017 年 3 月期间因病理而行超声引导下活检或手术的 63 例患者的 88 个浅表淋巴结。所有淋巴结均接受 CEUS 和 PET-CT 评估。记录 CEUS 和 PET-CT 参数,包括到达时间(AT)、达峰时间(TTP)、基础强度(BI)、峰值强度(PI)、上升斜率(AS)、下降斜率(DS)、时间-强度曲线下面积(AUC)、最大标准化摄取值(SUVmax)和平均标准化摄取值(SUVmean)。采用 Pearson 相关分析评估 CEUS 和 PET-CT 参数之间的相关性。

结果 在 88 个检查的淋巴结中,12 个为霍奇金淋巴瘤(HL),76 个为非霍奇金淋巴瘤(NHL)。CEUS 剂量参数(ΔI、AUC 和 AS)的变化与 PET-CT 结果(SUVmax 和 TLG)呈正相关。相关系数分别为 0.609、0.518、0.456、0.630、0.593 和 0.532。其余时间值(AT、TP 和 ΔT)与 PET-CT 结果呈负相关。相关系数分别为-0.239、-0.272、-0.284 和-0.377、-0.391 和-0.320。

结论 定量 CEUS 数据与 PET-CT 值相关,在淋巴瘤的诊断中有潜在应用价值。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d68a/6098669/322366b9315f/medscimonit-24-5558-g001.jpg