Suppr超能文献

应用同步多切片采集的盆腔淋巴结评估加速扩散加权成像:一项健康志愿者研究。

Accelerated diffusion-weighted imaging for lymph node assessment in the pelvis applying simultaneous multislice acquisition: A healthy volunteer study.

作者信息

Ciritsis Alexander, Rossi Cristina, Marcon Magda, Van Valerie Doan Phi, Boss Andreas

机构信息

Institute of Diagnostic and Interventional Radiology, University Hospital Zürich, Zürich, Switzerland.

出版信息

Medicine (Baltimore). 2018 Aug;97(32):e11745. doi: 10.1097/MD.0000000000011745.

Abstract

To evaluate the feasibility of accelerated simultaneous multislice diffusion weighted sequences (SMS-DWI) for lymph node detection in the abdominopelvic region. Sequences were evaluated regarding the number and depiction of lymph nodes detected with SMS-DWI compared with conventional diffusion weighted sequences, the most suitable SMS- acceleration factor, signal-to-noise ratio (SNR), and the overall acquisition time (TA).Eight healthy volunteers (4 men, 4 women; age range 21-39 years; median age 25 years) were examined in the pelvic region at 3T using a conventional DWI sequence and a SMS DWI sequence with different acceleration factors (AF: 2-3). Moreover, a SMS DWI sequence with AF 3 and higher slice resolution was applied. For morphological correlation of the lymph nodes and as a reference standard, an isotropic 3-dimensional T2-weighted fast-spin-echo sequence with high sampling efficiency (SPACE) was acquired. Two radiologists reviewed each DWI sequence and assessed the number of lymph nodes and the overall image quality. For each DWI sequence, SNR, SNR efficiency per time, contrast to noise (CNR), and ADC values were calculated. Values were statistically compared using a Wilcoxon test (P < .05).Overall, scan time of SMS-DWI with AF2 (AF3) decreased by 46.9% (57.2%) with respect to the conventional DWI. Compared with the SPACE sequence, the detection rate was 89.6% for conventional DWI, 69.4% for SMS-DWI with AF2, and 59.9% for SMS-DWI with AF3. The highly resolved SMS-DWI with AF3 leads to a scan time reduction of 46.9% and detection rate of 83.0%. SNR and CNR were lower in the accelerated sequences (up to 51.0%, P < .001) as compared with the conventional DWI. SNR efficiency decreased to 19.3% for AF2 and to 31.3% for AF3. In the highly resolved dataset, an SNR efficiency reduction of 51.2% was found.This study showed that lymph node detection in the abdominopelvic region with accelerated SMS-DWI sequences is feasible whereby an AF of 2 represents the best compromise between image quality, SNR, CNR, TA, and detection rate.

摘要

评估腹部盆腔区域加速同时多层扩散加权序列(SMS-DWI)用于淋巴结检测的可行性。将SMS-DWI与传统扩散加权序列相比,评估序列所检测到的淋巴结数量及显示情况、最合适的SMS加速因子、信噪比(SNR)和总采集时间(TA)。8名健康志愿者(4名男性,4名女性;年龄范围21 - 39岁;中位年龄25岁)在3T下于盆腔区域接受检查,使用传统DWI序列和具有不同加速因子(AF:2 - 3)的SMS DWI序列。此外,还应用了AF为3且具有更高层厚分辨率的SMS DWI序列。为了对淋巴结进行形态学对照并作为参考标准,采集了具有高采样效率的各向同性三维T2加权快速自旋回波序列(SPACE)。两名放射科医生查看每个DWI序列并评估淋巴结数量和整体图像质量。对于每个DWI序列,计算SNR、每时间的SNR效率、对比噪声(CNR)和ADC值。使用Wilcoxon检验进行统计学比较(P < 0.05)。总体而言,与传统DWI相比,AF2(AF3)的SMS-DWI扫描时间减少了46.9%(57.2%)。与SPACE序列相比,传统DWI的检测率为89.6%,AF2的SMS-DWI为69.4%,AF3的SMS-DWI为59.9%。具有AF3的高分辨率SMS-DWI导致扫描时间减少46.9%,检测率为83.0%。与传统DWI相比,加速序列中的SNR和CNR较低(高达51.0%,P < 0.001)。AF2的SNR效率降至19.3%,AF3降至31.3%。在高分辨率数据集中,发现SNR效率降低了51.2%。本研究表明,使用加速SMS-DWI序列在腹部盆腔区域进行淋巴结检测是可行的,其中AF为2代表了图像质量、SNR、CNR、TA和检测率之间的最佳折衷。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a149/6133413/567849482cee/medi-97-e11745-g005.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验