• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Using image processing for determination of settled sludge volume.

作者信息

Mullins Darragh, Coburn Derek, Hannon Louise, Jones Edward, Clifford Eoghan, Glavin Martin

机构信息

Electrical and Electronic Engineering, College of Engineering and Informatics, National University of Ireland, Galway, Republic of Ireland E-mail:

School of Physics, College of Science, National University of Ireland, Galway, Republic of Ireland.

出版信息

Water Sci Technol. 2018 Aug;78(1-2):390-401. doi: 10.2166/wst.2018.315.

DOI:10.2166/wst.2018.315
PMID:30101774
Abstract

Determination of the sludge volume index is key to describing the settling characteristics of sludge in the aeration process of wastewater treatment plants (WWTPs). The two core components of this calculation are the settled sludge volume (SSV) and suspended solids. While the measurement procedure for SSV is generally defined by national or international standards, in practice a wide variety of vessel sizes and shapes are used by operators to monitor WWTP performance. Furthermore, differences in how these tests are carried out can lead to poor data, inefficient WWTP operation and a lack of comparable metrics for WWTP operational monitoring. Thus, there is a requirement to improve operational performance of WWTPs to meet the increasingly stringent legislation regarding discharge limits. The aim of this study was to utilise a novel image-processing system (AutoSSV) to (i) determine its efficacy in describing SSV and (ii) measure and compare different methodologies for measurement of SSV. The AutoSSV system was tested using samples from various WWTPs and the results compared to those determined by standard manual measurement. Both standard and modified settlement tests were conducted on 30 mixed liquor samples, with modified settlement tests consistently resulting in lower SSV measurements. Results from the study showed a strong correlation between the SSV measurements provided by the AutoSSV system and results obtained from current manual measurement methods. The proposed technique would help to standardise the measurement in practice and increase the frequency of monitoring, particularly in small-scale rural WWTPs where there may not be permanent operators on site, and thus provide sufficient performance monitoring for efficient and effective operation.

摘要

相似文献

1
Using image processing for determination of settled sludge volume.
Water Sci Technol. 2018 Aug;78(1-2):390-401. doi: 10.2166/wst.2018.315.
2
Digital image processing and analysis for activated sludge wastewater treatment.用于活性污泥废水处理的数字图像处理与分析
Adv Exp Med Biol. 2015;823:227-48. doi: 10.1007/978-3-319-10984-8_13.
3
A novel image processing-based system for turbidity measurement in domestic and industrial wastewater.一种基于图像处理的新型系统,用于测量生活污水和工业废水中的浊度。
Water Sci Technol. 2018 Mar;77(5-6):1469-1482. doi: 10.2166/wst.2018.030.
4
Sludge settleability detection using automated SV30 measurement and its application to a field WWTP.利用自动 SV30 测量检测污泥沉降性能及其在现场 WWTP 中的应用。
Water Sci Technol. 2011;64(8):1743-9. doi: 10.2166/wst.2011.078.
5
Current operation state of wastewater treatment plants in urban China.中国城市污水处理厂的当前运行状况。
Environ Res. 2021 Apr;195:110843. doi: 10.1016/j.envres.2021.110843. Epub 2021 Feb 3.
6
Upflow anaerobic sludge blanket reactor--a review.上流式厌氧污泥床反应器——综述
Indian J Environ Health. 2001 Apr;43(2):1-82.
7
Improvement of primary settling performance with activated sludge.利用活性污泥提高初次沉淀性能。
Environ Technol. 2002 Apr;23(4):363-72. doi: 10.1080/09593332508618395.
8
Identifying different types of bulking in an activated sludge system through quantitative image analysis.通过定量图像分析识别活性污泥系统中的不同类型膨胀。
Chemosphere. 2011 Oct;85(4):643-52. doi: 10.1016/j.chemosphere.2011.07.012. Epub 2011 Aug 12.
9
Limit of stokesian settling concentration characterizes sludge settling velocity.斯托克斯沉降浓度极限表征了污泥的沉降速度。
Water Res. 2016 Mar 1;90:100-110. doi: 10.1016/j.watres.2015.12.007. Epub 2015 Dec 13.
10
Monitoring activated sludge settling properties using image analysis.利用图像分析监测活性污泥沉降特性。
Water Sci Technol. 2004;50(7):281-5.

引用本文的文献

1
Assessing the Dispersion Stability of Antimicrobial Fillers in Photosensitive Resin for Vat Polymerization 3D Printing.评估用于光固化3D打印的光敏树脂中抗菌填料的分散稳定性
3D Print Addit Manuf. 2024 Jun 18;11(3):e1334-e1342. doi: 10.1089/3dp.2022.0379. eCollection 2024 Jun.