Vyberg M, Miskowiak J, Nielsen S L, Fahrenkrug L, Thomsen H S
Cardiovasc Intervent Radiol. 1986;9(1):28-32. doi: 10.1007/BF02576981.
Angiodysplasia of the right colon may be difficult to diagnose. The usual methods of choice, selective abdominal angiography and colonoscopy, may be impracticable or fail. When bleeding occurs, 99mtechnetium blood-pool scintigraphy is a simple and reliable method of localizing vessel leakage. We present a case of an 84-year-old woman with severely bleeding angiodysplasia, where the source of bleeding was localized by means of scintigraphy using 99mTc in vivo labeled red blood cells. After right hemicolectomy, the angiodysplastic lesion was confirmed by specimen venography utilizing a barium gelatin mixture.
右半结肠血管发育异常可能难以诊断。常用的诊断方法,如选择性腹部血管造影和结肠镜检查,可能无法实施或检查失败。出血发生时,99m锝血池闪烁扫描是定位血管渗漏的一种简单可靠的方法。我们报告一例84岁严重出血性血管发育异常的女性病例,通过使用99mTc体内标记红细胞的闪烁扫描定位出血源。右半结肠切除术后,利用钡明胶混合物进行标本静脉造影证实了血管发育异常病变。