Clinic of Orthopaedics and Traumatology, Kantonsspital, Winterthur, Switzerland.
Clinic of Orthopaedics and Traumatology, Kantonsspital, Winterthur, Switzerland.
J Shoulder Elbow Surg. 2018 Nov;27(11):2077-2084. doi: 10.1016/j.jse.2018.06.009. Epub 2018 Aug 16.
The aim of this cadaveric study was to investigate different defined drill trajectories through the radial tuberosity for the placement of a cortical button and their proximity to the posterior interosseous nerve (PIN) by using the double-incision technique.
A total of 10 elbows from 5 fresh entire cadavers were used in this study. Detachment of the distal biceps tendon was performed to simulate its rupture. A standardized double-incision approach was performed, and the radial tuberosity was exposed in full pronation. A drill hole was applied perpendicular through the center of the tuberosity. Another 8 drill holes were applied with the same starting point at the tuberosity with defined trajectories. A cortical button was then placed through the center hole. The distances between the PIN and the exit holes of the different trajectories were measured. The cortical button was analyzed regarding muscle entrapment as well as its closest distance to the PIN.
Contact of the PIN and the drill hole was observed for 6 of the 9 trajectories; only the proximal-ulnar, ulnar, and ulnar-distal trajectories had no contact with the PIN in any of the experiments. No contact of the cortical button and the PIN was observed for the ulnar and distal-ulnar drill trajectories only. The minimal distance to the PIN was 1.6 mm for both.
Because of the potential risk of PIN injuries, the use of cortical button fixation in combination with the double-incision approach cannot be recommended.
本尸体研究的目的是通过双切口技术,研究通过桡骨结节的不同定义的钻孔轨迹,用于皮质纽扣的放置及其与骨间后神经(PIN)的接近程度。
本研究共使用了 5 具新鲜完整尸体的 10 个肘部。为了模拟其断裂,进行了远端肱二头肌肌腱的分离。进行了标准化的双切口入路,充分旋前暴露桡骨结节。垂直于结节中心应用钻一个孔。然后,用相同的起点在结节上应用另外 8 个具有定义轨迹的钻孔。通过中心孔放置皮质纽扣。测量 PIN 与不同轨迹出口孔之间的距离。分析皮质纽扣是否有肌肉嵌顿以及与 PIN 的最近距离。
在 9 个轨迹中的 6 个中观察到了 PIN 和钻孔之间的接触;只有近端尺侧、尺侧和尺侧远端的轨迹在任何实验中均未与 PIN 接触。仅在尺侧和远端尺侧钻孔轨迹中未观察到皮质纽扣和 PIN 的接触。与 PIN 的最小距离均为 1.6mm。
由于存在 PIN 损伤的潜在风险,因此不推荐皮质纽扣固定与双切口入路联合使用。