植入曲型保骨髋关节柄与标准长度直型髋关节柄后假体周围骨密度的变化:一项前瞻性、随机 DXA 分析的 5 年结果。

Periprosthetic Bone Mineral Density Changes After Implantation of a Curved Bone Preserving Hip Stem Compared to a Standard Length Straight Stem: 5-Yr Results of a Prospective, Randomized DXA-Analysis.

机构信息

Department of Orthopaedic Surgery, University of Ulm, Ulm, Germany.

Department of Orthopaedic Surgery, University of Ulm, Ulm, Germany.

出版信息

J Clin Densitom. 2019 Jan-Mar;22(1):96-103. doi: 10.1016/j.jocd.2018.07.007. Epub 2018 Jul 21.

Abstract

INTRODUCTION

The objective of this prospective, randomized study was to evaluate differences in periprosthetic bone mineral density changes in the proximal femur after implantation of a cementless bone preserving stem (Fitmore) compared to a cementless straight stem (CLS Spotorno).

METHODOLOGY

Periprosthetic bone mineral density was measured in 140 patients (aged 33-74 yr) before surgery, 7 d, 3, 12, and 60 mo postoperatively, using dual energy X-ray absorptiometry. The 1-yr results have already been published. The results of the first postoperative measurement served as the baseline value. Because of the different length of the 2 implants we used adapted Gruen zones to divide the periprosthetic bone in seven regions of interest with comparable length. Clinical results were recorded using the Western Ontario and McMaster Universities Arthritis Index and the Harris hip score.

RESULTS

Clinical findings showed comparable results in both groups at all follow-ups (p > 0.05). A total of 5 yr after surgery, the comparison of periprosthetic bone mineral density changes showed significant differences in regions of interests 3 (CLS -3.9% vs Fitmore -0.2%, p < 0.001) and 5 (CLS -3.6% vs Fitmore -1.3%, p = 0.0028) between both implants.

CONCLUSION

Despite the fact that no exclusive proximal load distribution could be observed, proximal periprosthetic bone loss in the proximal femur was less pronounced after implantation of the bone preserving stem than with the straight stem.

摘要

简介

本前瞻性、随机研究的目的是评估在植入非骨水泥保骨型(Fitmore)与非骨水泥直型(CLS Spotorno)股骨柄后,股骨近端的假体周围骨密度变化的差异。

方法

140 名患者(年龄 33-74 岁)在术前、术后 7 天、3、12 和 60 个月时使用双能 X 射线吸收法测量假体周围骨矿物质密度。1 年的结果已经发表。首次术后测量的结果作为基线值。由于两种植入物的长度不同,我们使用了适应性的 Gruen 分区,将假体周围的骨骼分为 7 个感兴趣区域,长度相当。临床结果采用 Western Ontario 和 McMaster 大学关节炎指数和 Harris 髋关节评分进行记录。

结果

在所有随访中,两组的临床结果均无显著差异(p>0.05)。术后 5 年,假体周围骨矿物质密度变化的比较显示,在两个植入物的感兴趣区域 3(CLS -3.9%比 Fitmore -0.2%,p<0.001)和 5(CLS -3.6%比 Fitmore -1.3%,p=0.0028)有显著差异。

结论

尽管没有观察到专门的近端负荷分布,但保骨型股骨柄植入后股骨近端的假体周围骨丢失程度比直型股骨柄植入后更不明显。