使用Fitmore或CLS股骨组件五年后结果相似。

Similar results after five years with the use of the Fitmore or the CLS femoral components.

作者信息

Rilby Karin, Mohaddes Maziar, Kärrholm Johan

机构信息

Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Mölndal, Sweden.

Department of Orthopaedic Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden.

出版信息

Bone Jt Open. 2023 May 3;4(5):306-314. doi: 10.1302/2633-1462.45.BJO-2023-0007.R1.

Abstract

Although the Fitmore Hip Stem has been on the market for almost 15 years, it is still not well documented in randomized controlled trials. This study compares the Fitmore stem with the CementLeSs (CLS) in several different clinical and radiological aspects. The hypothesis is that there will be no difference in outcome between stems. In total, 44 patients with bilateral hip osteoarthritis were recruited from the outpatient clinic at a single tertiary orthopaedic centre. The patients were operated with bilateral one-stage total hip arthroplasty. The most painful hip was randomized to either Fitmore or CLS femoral component; the second hip was operated with the femoral component not used on the first side. Patients were evaluated at three and six months and at one, two, and five years postoperatively with patient-reported outcome measures, radiostereometric analysis, dual-energy X-ray absorptiometry, and conventional radiography. A total of 39 patients attended the follow-up visit at two years (primary outcome) and 35 patients at five years. The primary outcome was which hip the patient considered to have the best function at two years. At two and five years, more patients considered the hip with the CLS femoral component as superior but without a statistically significant difference. There were no differences in clinical outcome, magnitude of femoral component migration, or change of bone mineral density at five years. At three months, the Fitmore femoral component had subsided a median -0.71 mm (interquartile range (IQR) -1.67 to -0.20) and the CLS femoral component -0.70 mm (IQR -1.53 to -0.17; p = 0.742). In both groups the femoral head centre had migrated posteriorly (Fitmore -0.17 mm (IQR -0.98 to -0.04) and CLS -0.23 mm (IQR -0.87 to 0.07; p = 0.936)). After three months neither of the femoral components showed much further migration. During the first postoperative year, one Fitmore femoral component was revised due to aseptic loosening. Up to five years, we found no statistically significant difference in outcomes between the Fitmore and the CLS femoral components. The slightly worse outcomes, including one revised hip because of loosening, speaks against the hypothesis that the Fitmore femoral component should be advantageous compared to the CLS if more patients had been recruited to this study.

摘要

尽管Fitmore髋关节柄已经上市近15年,但在随机对照试验中的记录仍然不充分。本研究在几个不同的临床和放射学方面将Fitmore柄与无骨水泥(CLS)柄进行了比较。假设是两种柄在结果上不会有差异。总共从一家单一的三级骨科中心的门诊招募了44例双侧髋关节骨关节炎患者。患者接受双侧一期全髋关节置换术。最疼痛的髋关节被随机分配使用Fitmore或CLS股骨假体;另一侧髋关节使用第一侧未使用的股骨假体进行手术。在术后3个月、6个月以及1年、2年和5年时,使用患者报告的结局指标、放射立体测量分析、双能X线吸收法和传统X线摄影对患者进行评估。共有39例患者参加了2年的随访(主要结局),35例患者参加了5年的随访。主要结局是患者认为在2年时功能最佳的是哪一侧髋关节。在2年和5年时,更多患者认为使用CLS股骨假体的髋关节更优,但差异无统计学意义。在5年时,临床结局、股骨假体移位幅度或骨密度变化方面没有差异。在3个月时,Fitmore股骨假体的下沉中位数为-0.71mm(四分位间距(IQR)-1.67至-0.20),CLS股骨假体为-0.70mm(IQR -1.53至-0.17;p = 0.742)。两组中股骨头中心均向后移位(Fitmore为-0.17mm(IQR -0.98至-0.04),CLS为-0.23mm(IQR -0.87至0.07;p = 0.936))。3个月后,两种股骨假体均未显示出进一步的明显移位。在术后的第一年,有一个Fitmore股骨假体因无菌性松动而进行了翻修。直到5年,我们发现Fitmore和CLS股骨假体在结局上没有统计学上的显著差异。包括因松动而翻修的一侧髋关节在内的略差结局,与如果本研究招募更多患者Fitmore股骨假体应比CLS更具优势的假设相悖。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验