Kaniewska Malwina, de Beus Johannes Maria, Ahlhelm Frank, Mameghani Alexander, Eid Karim, Kubik-Huch Rahel A, Anderson Suzanne E
1 Institute of Radiology, Kantonsspital Baden, Baden, Switzerland.
2 Centre for Orthopedic Surgery, Kantonsspital Aarau und Baden, Baden, Switzerland.
Acta Radiol. 2019 Jun;60(6):742-748. doi: 10.1177/0284185118796673. Epub 2018 Aug 24.
Whole spine localizers (WS-loc) of magnetic resonance imaging (MRI) are performed for enumeration of the vertebrae but they can be also used for the evaluation of the spine.
To assess the accuracy of fracture detection using WS-locs of MRI and compare the findings with standard high-resolution short tau inversion recovery (STIR) sequences, and to determine whether the review of WS-locs is useful and if additional information can be gained by assessing the thoracic spine section of the WS-locs.
A total of 298 magnetic resonance (MR) examinations of the lumbar spine with WS-locs were evaluated. Two independent readers reviewed the images. In case of fracture detection, further characterization of the fracture was performed. To assess inter-reader agreement, unweighted Cohen's kappa with 95% confidence intervals (CI) and Phi coefficients were calculated.
The study sample included 187 female and 111 male patients (age range = 65-94 years; median age = 75.0 years). The WS-locs detected 42 fractures of the lumbar spine and 36 of the thoracic spine. Inter-reader agreement for fracture detection in the lumbar and thoracic spine was strong (K = 0.87, 95% CI = 0.78-0.95, Phi = 0.87, and K = 0.88, 95% CI = 0.79-0.96, Phi = 0.88, respectively).
WS-locs from MR examinations of the lumbar spine provide a good diagnostic tool for the detection and evaluation of unsuspected vertebral fractures. WS-locs show strong inter-reader agreement for fracture detection in the thoracic and lumbar spine.
磁共振成像(MRI)的全脊柱定位器(WS-loc)用于对椎体进行计数,但也可用于评估脊柱。
评估使用MRI的WS-loc检测骨折的准确性,并将结果与标准高分辨率短tau反转恢复(STIR)序列进行比较,以确定查看WS-loc是否有用,以及通过评估WS-loc的胸椎部分是否能获得更多信息。
对总共298例带有WS-loc的腰椎磁共振(MR)检查进行了评估。两名独立的阅片者对图像进行了审查。一旦检测到骨折,便对骨折进行进一步的特征描述。为评估阅片者间的一致性,计算了具有95%置信区间(CI)的非加权Cohen's kappa系数和Phi系数。
研究样本包括187名女性和111名男性患者(年龄范围=65 - 94岁;中位年龄=75.0岁)。WS-loc检测到42例腰椎骨折和36例胸椎骨折。阅片者间对腰椎和胸椎骨折检测的一致性很强(K分别为0.87,95%CI = 0.78 - 0.95,Phi = 0.87;以及K为0.88,95%CI = 0.79 - 0.96,Phi = 0.88)。
腰椎MR检查中的WS-loc为检测和评估未被怀疑的椎体骨折提供了一种良好的诊断工具。WS-loc在胸椎和腰椎骨折检测方面显示出很强的阅片者间一致性。