Target analysis using liquid chromatography-tandem mass spectrometry is applied for rapidly detecting various prohibited doping substances. Frequent modification is required as additional substances are prohibited. We developed and validated a non-target screening method requiring no further modification because it analyzes the full spectrum of data in fixed m/z ranges. Urine samples were extracted using solid-phase extraction and analyzed by employing a method that combines full scan and variable data independent acquisition using high-resolution mass spectrometry; and all prohibited substances in the urine samples were successfully detected using our screening method. The method was validated in terms of specificity (no interferences), recoveries (29%-131%), matrix effects (35%-237%), limites of detection (0.0002-100 ng/mL), and intra- and inter-day precisions (coefficients of variation lower than 25%). The applicability of this method to doping tests was evaluated by analyzing 14 urine samples. As a result, the non-target screening method is efficient for conducting anti-doping tests because it can be applied without any further modification to prohibited drugs as well as to unknown targets that can be prohibited in the future.
采用液相色谱-串联质谱法进行靶向分析,可快速检测各种禁用兴奋剂物质。随着更多物质被禁用,需要频繁进行修改。我们开发并验证了一种无需进一步修改的非靶向筛选方法,因为它可以分析固定 m/z 范围内的全谱数据。使用固相萃取法提取尿液样本,采用全扫描和可变数据非依赖性采集相结合的方法进行分析,使用高分辨率质谱法;并使用我们的筛选方法成功检测到尿液样本中的所有禁用物质。该方法在特异性(无干扰)、回收率(29%-131%)、基质效应(35%-237%)、检测限(0.0002-100ng/mL)和日内及日间精密度(变异系数低于 25%)方面进行了验证。通过分析 14 个尿液样本,评估了该方法在兴奋剂检测中的适用性。结果表明,非靶向筛选方法对于进行反兴奋剂测试非常有效,因为它可以无需进一步修改即可应用于禁用药物以及未来可能被禁用的未知目标。