Suppr超能文献

[牙科局部麻醉下热成像评估微循环水平的可能性]

[Possibilities of thermographic rating the level of microcirculation with local anesthesia in dentistry].

作者信息

Vasil'ev Yu L, Rabinovich S A, Dydykin S S, Logachev V A, Pikhlak U A

机构信息

Peoples' Friendship University of Russia, Institute of Medicine.

A.I. Evdokimov Moscow state university of medicine and dentistry, dental department.

出版信息

Stomatologiia (Mosk). 2018;97(4):4-7. doi: 10.17116/stomat2018970414.

Abstract

UNLABELLED

It is known that the reduction of blood vessels by epinephrine that are part of the local anesthetic leads to a decrease in oxygen intake and the development of hypoxia, which has a significant effect on the excitability of nerve fibers. This is due to the fact that epinephrine is present in the local anesthetic cartridge, which helps to reduce, until termination, microcirculation in the depot area, which leads to local hypothermia. With the introduction of local anesthetics, the temperature of which is significantly lower than the depot temperature, the patient experiences severe discomfort, which is associated with unsuccessful local anesthesia. The goal of the study was the need to analyze the feasibility of using the thermography method in assessing the degree of ischemia of the soft tissues of the maxillofacial region against the background of local anesthesia with a different concentration of epinephrine in dentistry.

MATERIAL AND METHODS

In the pilot study, 22 healthy volunteers aged between 29-35 years of both sexes participated. To assess the degree of external vasoconstriction, a buccal region was chosen near the maxilla. Infiltration anesthesia was used with a 4% solution of articaine with epinephrine 1: 100 000 and 1: 200 000 at a dosage of 0.5-0.7 ml. The temperature distribution in the study area was estimated using a thermal imager Nec InfReC Thermo Gear G30.

RESULTS

The study showed that the use of epinephrine in local anesthetics naturally has a moderate effect on hemodynamics in areas adjacent to the anesthesia depot. When using a low concentration of epinephrine (1:200 000), the projection hyperthermia of the skin is determined. Perhaps this is due to the activation of microcirculation due to an increase in capillary blood flow in the region above the zone of action of the epinephrine. From the point of view of physiological arterial hyperemia, this mechanism carries positive properties, since leads to an increase in tissue oxygenation. When using a high concentration of epinephrine (1:100 000), the zone of hypothermia of the skin is determined, which corresponds to the phenomenon of angiospastic ischemia.

摘要

未标注

已知局部麻醉剂中的肾上腺素会使血管减少,导致氧气摄入量降低和缺氧的发生,这对神经纤维的兴奋性有显著影响。这是因为局部麻醉药筒中含有肾上腺素,它有助于在注射部位直至注射结束时减少微循环,从而导致局部体温过低。当注射温度明显低于注射部位温度的局部麻醉剂时,患者会感到严重不适,这与局部麻醉失败有关。本研究的目的是分析在牙科中使用不同浓度肾上腺素进行局部麻醉的背景下,利用热成像方法评估颌面部软组织缺血程度的可行性。

材料与方法

在初步研究中,22名年龄在29 - 35岁之间的健康志愿者(男女均有)参与。为评估外周血管收缩程度,选择上颌附近的颊部区域。采用含肾上腺素1:100000和1:200000的4%阿替卡因溶液进行浸润麻醉,剂量为0.5 - 0.7毫升。使用热成像仪Nec InfReC Thermo Gear G30估计研究区域的温度分布。

结果

研究表明,局部麻醉剂中使用肾上腺素自然会对与麻醉注射部位相邻区域的血流动力学产生适度影响。使用低浓度肾上腺素(1:200000)时,可确定皮肤投影区体温升高。这可能是由于肾上腺素作用区域上方区域的毛细血管血流增加导致微循环激活。从生理性动脉充血的角度来看,这种机制具有积极作用,因为它会导致组织氧合增加。使用高浓度肾上腺素(1:100000)时,可确定皮肤低温区,这与血管痉挛性缺血现象相对应。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验