OBJECTIVE

We investigated how the active electrode placement site influences compound muscle action potential (CMAP) configuration of the upper trapezius muscle (TM).

METHODS

A nerve conduction study of the accessory nerve was performed, and the CMAPs obtained with two different placement sites, i.e., placement of the active recording electrode on the belly of the upper TM (CMAP-) and placement of the electrode 2 cm behind the belly (CMAP-), were compared. CMAPs were also obtained with the active recording electrode placed in the supraspinous fossa (CMAP-).

RESULTS

All CMAPs were recorded from 21 healthy volunteers. The mean peak-to-peak amplitude of CMAP- was 3.4 mV higher than that of CMAP- (11.0 ± 4.0 mV vs. 14.4 ± 4.9 mV; P < 0.01). The mean peak-to-peak amplitude of CMAP- was 10.3 ± 5.0 mV.

CONCLUSIONS

CMAP of the upper TM was always higher when the active recording electrode was placed 2 cm behind the belly of the muscle.

SIGNIFICANCE

When stimulating the accessory nerve, a current spread occurs to the C5 spinal nerve root and another CMAP originating from the supraspinatus muscle occurs in the supraspinous fossa. The volume conduction from the supraspinatus muscle affects the active recording electrode on the TM, resulting in an increase in CMAP amplitude.

摘要

目的

我们研究了有源电极放置部位如何影响上斜方肌(TM)的复合肌肉动作电位(CMAP)形态。

方法

对副神经进行神经传导研究,比较在两个不同放置部位获得的CMAP,即有源记录电极置于上TM肌腹上(CMAP-)和置于肌腹后方2厘米处(CMAP-)。有源记录电极置于冈上窝时也获得了CMAP(CMAP-)。

结果

从21名健康志愿者身上记录到了所有CMAP。CMAP-的平均峰峰值幅度比CMAP-高3.4mV(11.0±4.0mV对14.4±4.9mV;P<0.01)。CMAP-的平均峰峰值幅度为10.3±5.0mV。

结论

当有源记录电极置于肌肉肌腹后方2厘米处时,上TM的CMAP总是更高。

意义

刺激副神经时,电流扩散至上5神经根,冈上窝会出现源自冈上肌的另一个CMAP。冈上肌的容积传导影响TM上的有源记录电极,导致CMAP幅度增加。