High complication rates were reported with the telescopic nail technique systems. To overcome such technical difficulties, we designed a corkscrew-tipped telescopic nail (CTTN). We biomechanically compared its pullout strength with that of two other tip designs. We used CTTN in 17 patients with osteogenesis imperfecta and reported their preliminary results. Average patient age was 82.6 months, and mean follow-up was 32.0±6 months. Telescoping and osteotomy site healing were assessed using radiological studies. Successful telescoping with event-free osteotomy site healing was achieved in 94.1% of patients; limited telescoping and delayed union were detected in one case each. Our results show that CTTN provides sufficient pullout strength and reduced complication rates compared with other designs.
据报道, telescopic nail技术系统的并发症发生率很高。为了克服这些技术难题,我们设计了一种螺旋尖端伸缩钉(CTTN)。我们对其拔出强度与其他两种尖端设计的拔出强度进行了生物力学比较。我们将CTTN应用于17例成骨不全患者,并报告了他们的初步结果。患者平均年龄为82.6个月,平均随访时间为32.0±6个月。使用放射学研究评估伸缩和截骨部位的愈合情况。94.1%的患者实现了成功伸缩且截骨部位无并发症愈合;各有1例出现有限伸缩和延迟愈合。我们的结果表明,与其他设计相比,CTTN具有足够的拔出强度并降低了并发症发生率。