Spada Eva, Perego Roberta, Viñals Flórez Luis Miguel, Del Rosario Perlado Chamizo Maria, Baggiani Luciana, Dall'Ara Paola, Proverbio Daniela
Veterinary Transfusion Research Laboratory (Spada, Perego, Baggiani, Proverbio) and Department of Veterinary Medicine (Dall'Ara), University of Milan, Milan, Italy.
Centro de Transfusión Veterinario, Madrid, Spain (Viñals Flórez).
J Vet Diagn Invest. 2018 Nov;30(6):911-916. doi: 10.1177/1040638718806023. Epub 2018 Oct 3.
We compared 3 major cross-match (XM) tests to identify dog erythrocyte antigen (DEA) 7 blood incompatibilities in dogs as a result of anti-DEA 7 antibodies: gel (GEL), standard tube (TUBE) agglutination, and immunochromatography strips (STRIP). Blood samples from 42 dogs were typed for DEA 7; 2 tested DEA 7-positive (DEA 7+). The 40 DEA 7-negative (DEA 7-) plasma samples were cross-matched against the 2 DEA 7+ and 3 DEA 7- red blood cell (RBC) samples by GEL to identify samples with anti-DEA 7 antibodies. Twenty DEA 7- plasma samples without and with anti-DEA 7 antibodies were cross-matched with samples of the 2 DEA 7+ RBCs in a double-blind fashion using the TUBE and STRIP XM methods. GEL results were used as the reference method for comparison. To determine relationships between results, 2 × 2 tables were used. Cohen kappa coefficient (κ) was calculated between results of GEL and the other 2 methods. With GEL, 21 of 40 XM tests were positive and 19 of 40 negative for anti-DEA 7 antibodies. The same results were obtained by TUBE, whereas only 1 of 40 XM tests was positive by STRIP. There was a statistically significant relationship between results of GEL and TUBE ( p < 0.000) with perfect agreement (κ = 1.000), but not between GEL and STRIP results ( p = 1.000) in which agreement was equivalent to chance (κ = 0.0453). The GEL and TUBE XM tests, but not STRIP, are useful methods for identification of DEA 7 incompatibilities caused by anti-DEA 7 antibodies.
我们比较了3种主要的交叉配血(XM)试验,以鉴定犬由于抗犬红细胞抗原(DEA)7抗体导致的犬红细胞血型不相容性:凝胶(GEL)法、标准试管(TUBE)凝集法和免疫层析条(STRIP)法。对42只犬的血样进行DEA 7血型鉴定;2只检测为DEA 7阳性(DEA 7+)。通过GEL法将40份DEA 7阴性(DEA 7-)血浆样本与2份DEA 7+和3份DEA 7-红细胞(RBC)样本进行交叉配血,以鉴定含有抗DEA 7抗体的样本。使用TUBE和STRIP XM方法,以双盲方式将20份不含和含有抗DEA 7抗体的DEA 7-血浆样本与2份DEA 7+红细胞样本进行交叉配血。GEL结果用作比较的参考方法。为了确定结果之间的关系,使用了2×2列联表。计算GEL结果与其他两种方法结果之间的Cohen卡帕系数(κ)。采用GEL法时,40次交叉配血试验中有21次抗DEA 7抗体呈阳性,19次呈阴性。TUBE法得到了相同的结果,而STRIP法在40次交叉配血试验中只有1次呈阳性。GEL和TUBE结果之间存在统计学显著关系(p<0.000),一致性极佳(κ=1.000),但GEL和STRIP结果之间不存在这种关系(p=1.000),其一致性等同于随机情况(κ=0.0453)。GEL和TUBE交叉配血试验是鉴定由抗DEA 7抗体引起的DEA 7血型不相容性的有用方法,而STRIP法不是。