Suppr超能文献

用于评估马输血相容性的试管法、凝胶法和免疫层析试纸条法的比较

Comparison of Tube, Gel, and Immunochromatographic Strip Methods for Evaluation of Blood Transfusion Compatibility in Horses.

作者信息

Luethy D, Owens S D, Stefanovski D, Nolen-Walston R, Giger U

机构信息

Department of Clinical Studies-New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, PA.

Department of Pathology, Microbiology and Immunology, University of California, Davis, School of Veterinary Medicine, Davis, CA.

出版信息

J Vet Intern Med. 2016 Nov;30(6):1864-1871. doi: 10.1111/jvim.14604. Epub 2016 Oct 22.

Abstract

BACKGROUND

Assessment of blood compatibility, typically by tube agglutination (TUBE) and hemolysis crossmatch or, less commonly, by blood typing and alloantibody screening, often is performed before blood transfusion in horses. In contrast, gel column (GEL) and immunochromatographic strip (STRIP) techniques are preferred for compatibility testing in dogs and cats.

OBJECTIVE

To determine the accuracy of novel and standard crossmatch and typing methods.

ANIMALS

Thirty-eight healthy horses, previously blood typed and alloantibody screened.

METHODS

TUBE and GEL crossmatches were performed on 146 different recipient-donor pairs with 56 incompatible TUBE crossmatches. Crossmatches were compared by nonparametric area under the curve of receiver operating characteristic (AUC-ROC) analyses. Horses also were blood typed by the novel immunochromatographic Ca typing STRIP.

RESULTS

Compared to TUBE crossmatch, GEL had excellent accuracy for agglutination (AUC-ROC = 0.903), but marginal accuracy for hemolysis (AUC-ROC = 0.639). Compared to macroscopic TUBE, microscopic TUBE had excellent accuracy for agglutination (AUC-ROC = 0.912). The predicted crossmatch compatibility based on blood type and alloantibody assay showed excellent accuracy compared to TUBE and GEL (AUC-ROC = 0.843 and 0.897, respectively). However, there were more recipient-donor pairs identified as incompatible by both TUBE and GEL than predicted by blood type and antibody screen, suggesting the presence of unidentified alloantibodies. A Ca typing STRIP exhibited 100% sensitivity and specificity for the 35 Ca+ and 3 Ca- horses tested.

CONCLUSIONS AND CLINICAL RELEVANCE

Gel column crossmatch and Ca typing immunochromatographic strip are simple and accurate methods to evaluate clinical blood compatibility.

摘要

背景

马输血前通常通过试管凝集试验(TUBE)和溶血交叉配血来评估血液相容性,较少情况下通过血型鉴定和同种抗体筛查来评估。相比之下,凝胶柱(GEL)和免疫层析条(STRIP)技术是犬猫相容性检测的首选方法。

目的

确定新型和标准交叉配血及血型鉴定方法的准确性。

动物

38匹健康马,此前已进行血型鉴定和同种抗体筛查。

方法

对146对不同的受血者 - 供血者进行TUBE和GEL交叉配血,其中56对TUBE交叉配血不相容。通过非参数接受者操作特征曲线下面积(AUC - ROC)分析比较交叉配血结果。还使用新型免疫层析钙分型STRIP对马进行血型鉴定。

结果

与TUBE交叉配血相比,GEL在凝集方面准确性极佳(AUC - ROC = 0.903),但在溶血方面准确性一般(AUC - ROC = 0.639)。与宏观TUBE相比,微观TUBE在凝集方面准确性极佳(AUC - ROC = 0.912)。基于血型和同种抗体检测预测的交叉配血相容性与TUBE和GEL相比准确性极佳(分别为AUC - ROC = 0.843和0.897)。然而,TUBE和GEL鉴定为不相容的受血者 - 供血者对比血型和抗体筛查预测的更多,提示存在未识别的同种抗体。对于35匹Ca +马和3匹Ca -马进行检测,钙分型STRIP的敏感性和特异性均为100%。

结论及临床意义

凝胶柱交叉配血和钙分型免疫层析条是评估临床血液相容性的简单且准确的方法。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1897/5115201/e4bb66ea4cd5/JVIM-30-1864-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验