J Appl Physiol (1985). 2018 Dec 1;125(6):1749-1759. doi: 10.1152/japplphysiol.00640.2018. Epub 2018 Oct 4.
Isoflurane (ISO) is a commonly used anesthetic that offers rapid recovery for laboratory animal research. Initial studies indicated no difference in arterial Pco ( ) or pH between conscious (NO ISO) and 1% ISO-exposed CD-1 mice. Our laboratory investigated whether arterial blood sampling with 1% ISO is a suitable alternative to NO ISO sampling for monitoring ventilation in a commonly studied mouse strain. We hypothesized similar blood chemistry, breathing patterns, and cardiovascular responses with NO ISO and 1% ISO. C57BL/6J mice underwent unrestrained barometric plethysmography to quantify the pattern of breathing. Mice exposed to hypoxic and hypercapnic gas under 1% ISO displayed blunted responses; with air, there were no breathing differences. Blood pressure and heart rate were not different between NO ISO and 1% ISO-exposed mice breathing air. Oxygen saturation was not different between groups receiving 2% ISO, 1% ISO, or air. Breathing frequency stabilized at ~11 min of 1% ISO following 2% ISO exposure, suggesting that 11 min is the optimal time for a sample in C57BL/6J mice. Blood samples at 1% ISO and NO ISO revealed no differences in blood pH and in C57BL/6J mice. Overall, this method reveals similar arterial blood sampling values in awake and 1% ISO CD-1 and C57BL/6J mice exposed to air. Although this protocol may be appropriate in other mouse strains when a conscious sample is not feasible, caution is warranted first to identify breathing frequency responses at 1% ISO to tailor the protocol. NEW & NOTEWORTHY Conscious arterial blood sampling is influenced by extraneous factors and is a challenging method due to the small size of mice. Through a series of experiments, we show that arterial blood sampling with 1% isoflurane (ISO) is an alternative to awake sampling in C57BL/6J and CD-1 male mice breathing air. Monitoring breathing frequency during 1% ISO is important to the protocol and should be closely followed to confirm adequate recovery after the catheter implantation.
异氟烷(ISO)是一种常用的麻醉剂,可为实验室动物研究提供快速恢复。最初的研究表明,清醒(NO ISO)和 1% ISO 暴露的 CD-1 小鼠之间的动脉 Pco 2( )或 pH 没有差异。我们的实验室研究了在常用的研究小鼠品系中,用 1% ISO 进行动脉采血是否可以替代 NO ISO 采样来监测通气。我们假设 NO ISO 和 1% ISO 具有相似的血液化学、呼吸模式和心血管反应。C57BL/6J 小鼠接受不受限制的气压容积描记术以量化呼吸模式。暴露于 1% ISO 下的缺氧和高碳酸血症气体的小鼠显示出反应迟钝;而在空气中,呼吸没有差异。在呼吸空气的 NO ISO 和 1% ISO 暴露的小鼠中,血压和心率没有差异。接受 2% ISO、1% ISO 或空气的小鼠之间的氧饱和度没有差异。在接受 2% ISO 暴露后,1% ISO 的呼吸频率稳定在 11 分钟左右,这表明 11 分钟是 C57BL/6J 小鼠样本的最佳时间。1% ISO 和 NO ISO 的血液样本显示 C57BL/6J 小鼠的血液 pH 和 没有差异。总体而言,该方法在清醒和 1% ISO CD-1 和 C57BL/6J 小鼠中显示出类似的动脉血液采样值,这些小鼠暴露于空气中。尽管当无法获得清醒样本时,该方案可能适用于其他小鼠品系,但首先需要谨慎识别 1% ISO 下的呼吸频率反应,以定制方案。新意和值得注意之处 清醒的动脉血液采样受到外来因素的影响,并且由于小鼠的体积小,这是一种具有挑战性的方法。通过一系列实验,我们表明,在 C57BL/6J 和 CD-1 雄性小鼠呼吸空气时,用 1% 异氟烷(ISO)进行动脉采血是清醒采样的替代方法。在 1% ISO 期间监测呼吸频率对于方案很重要,并且应该密切关注,以确认在导管植入后恢复充分。