Suppr超能文献

是时候把握猪促肾上腺皮质激素的机遇了——猪序列促肾上腺皮质激素与醋酸二十四肽促皮质素在检测健康个体下丘脑-垂体-肾上腺轴中的比较。

It is Time to Carpe Diem with Porcine ACTH - A Comparison of Porcine Sequence Corticotropin to Tetracosactide Hexaacetate in Testing the Hypothalamic Pituitary Adrenal Axis in Healthy Individuals.

作者信息

Wagmode Nalini B, Mathew Vivek, Bantwal Ganapathy, Ayyar Vageesh, George Belinda, Patanjali C P, Michael John

机构信息

Department of Endocrinology, St. John's Hospital and Medical College, Bengaluru, Karnataka, India.

出版信息

Indian J Endocrinol Metab. 2018 Sep-Oct;22(5):636-640. doi: 10.4103/ijem.IJEM_114_18.

Abstract

CONTEXT

Our literature search revealed that the use of porcine sequence corticotropin has not been validated against tetracosactide hexaacetate in a healthy population.

AIMS

To study the efficacy of using porcine sequence corticotropin in comparison with tetracosactide hexaacetate in the evaluation of hypothalamo pituitary adrenal (HPA) axis.

MATERIALS AND METHODS

Fifteen healthy volunteers were enrolled. Serum cortisol was measured at 0 minute in all subjects and at 30 and 60 minutes after tetracosactide hexaacetate 250 μg intravenously. Four weeks later, serum cortisol level was measured at 0 minute and at 30 and 60 minutes following 24 units of porcine sequence corticotropin given intramuscularly.

RESULTS

Mean serum cortisol values with tetracosactide were 30.3 (±7.83) μg/dl and 31.27 (±7.36) μg/dl at 30 and 60 minutes, respectively. The mean cortisol values with porcine sequence corticotropin were 26.33 (±5.47) μg/dl and 31.59 (±6.40) μg/dl at 30 and 60 minutes, respectively. All subjects had a response qualified as normal or adequate at 30 minutes itself. Mean peak serum cortisol response was 32.65 (±7.76) μg/dl in tetracosactide group and 31.59 (±6.4) μg/dl in porcine sequence corticotropin group, and the responses in two groups were comparable ( = 0.686). There were no immediate side effects in both groups, with a lower cost of procedure in the porcine corticotropin group.

CONCLUSION

Our study established the efficacy of porcine sequence corticotropin in testing the adequacy of HPA axis in healthy individuals. Our study also revealed that, the intactness of the HPA axis could be confirmed as early as 30 minutes in healthy individuals.

摘要

背景

我们的文献检索显示,在健康人群中,猪序列促肾上腺皮质激素的使用尚未与醋酸二十四肽促皮质素进行过对比验证。

目的

研究猪序列促肾上腺皮质激素与醋酸二十四肽促皮质素相比,在评估下丘脑 - 垂体 - 肾上腺(HPA)轴方面的疗效。

材料与方法

招募了15名健康志愿者。所有受试者在0分钟时测量血清皮质醇,静脉注射250μg醋酸二十四肽促皮质素后30分钟和60分钟时再次测量。四周后,肌肉注射24单位猪序列促肾上腺皮质激素,在0分钟、30分钟和60分钟时测量血清皮质醇水平。

结果

使用醋酸二十四肽促皮质素时,30分钟和60分钟时血清皮质醇的平均水平分别为30.3(±7.83)μg/dl和31.27(±7.36)μg/dl。使用猪序列促肾上腺皮质激素时,30分钟和60分钟时皮质醇的平均水平分别为26.33(±5.47)μg/dl和31.59(±6.40)μg/dl。所有受试者在30分钟时的反应均符合正常或充分的标准。醋酸二十四肽促皮质素组血清皮质醇反应峰值平均为32.65(±7.76)μg/dl,猪序列促肾上腺皮质激素组为31.59(±6.4)μg/dl,两组反应具有可比性(P = 0.686)。两组均无即刻副作用,猪促肾上腺皮质激素组的操作成本更低。

结论

我们的研究证实了猪序列促肾上腺皮质激素在检测健康个体HPA轴功能是否正常方面的有效性。我们的研究还表明,在健康个体中,早在30分钟时就能确认HPA轴的完整性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6fec/6166546/f0637e825ad3/IJEM-22-636-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验