Abstract

OBJECTIVES

To assess the literature on the accuracy of static computer-assisted implant surgery in implant dentistry.

MATERIALS AND METHODS

Electronic and manual literature searches were conducted to collect information about the accuracy of static computer-assisted implant systems. Meta-regression analysis was performed to summarise the accuracy studies.

RESULTS

From a total of 372 articles. 20 studies, one randomised controlled trial (RCT), eight uncontrolled retrospective studies and 11 uncontrolled prospective studies were selected for inclusion for qualitative synthesis. A total of 2,238 implants in 471 patients that had been placed using static guides were available for review. The meta-analysis of the accuracy (20 clinical) revealed a total mean error of 1.2 mm (1.04 mm to 1.44 mm) at the entry point, 1.4 mm (1.28 mm to 1.58 mm) at the apical point and deviation of 3.5°(3.0° to 3.96°). There was a significant difference in accuracy in favour of partial edentulous comparing to full edentulous cases.

CONCLUSION

Different levels of quantity and quality of evidence were available for static computer-aided implant surgery (s-CAIS). Based on the present systematic review and its limitations, it can be concluded that the accuracy of static computer-aided implant surgery is within the clinically acceptable range in the majority of clinical situations. However, a safety marge of at least 2 mm should be respected. A lack of homogeneity was found in techniques adopted between the different authors and the general study designs.

摘要

目的

评估静态计算机辅助种植手术在种植牙科中的准确性的文献。

材料与方法

电子和手动文献检索收集有关静态计算机辅助种植系统准确性的信息。进行荟萃回归分析以总结准确性研究。

结果

共 372 篇文章,其中 20 项研究,1 项随机对照试验(RCT)、8 项非对照回顾性研究和 11 项非对照前瞻性研究被选入定性综合分析。共有 471 名患者的 2238 个种植体可用于审查,这些种植体是使用静态导板植入的。准确性(20 项临床研究)的荟萃分析显示,入口处的总平均误差为 1.2mm(1.04mm 至 1.44mm),根尖处为 1.4mm(1.28mm 至 1.58mm),偏差为 3.5°(3.0°至 3.96°)。部分无牙颌与全口无牙颌相比,准确性有显著差异。

结论

静态计算机辅助种植手术(s-CAIS)的证据数量和质量存在不同水平。基于本系统综述及其局限性,可以得出结论,在大多数临床情况下,静态计算机辅助种植手术的准确性在临床可接受范围内。然而,应至少保留 2mm 的安全余量。作者之间采用的技术和总体研究设计存在不一致性。