Tuzimski Tomasz, Pieniążek Dominika, Buszewicz Grzegorz, Teresiński Grzegorz
Medical University in Lublin, Department of Physical Chemistry, Chair of Chemistry, 4A Chodźki St, Lublin 20-093, Poland.
Medical University of Lublin, Department of Forensic Medicine, 8b Jaczewskiego St, Lublin 20-090, Poland.
J AOAC Int. 2018 Oct 17. doi: 10.5740/jaoacint.18-0297.
Different extraction and clean-up protocols, based on either the dispersive solid-phase extraction (d-SPE) and the quick, easy, cheap, effective, rugged, and safe (QuEChERS) approach, were optimized and compared for the determination of selected bisphenols such as bisphenol A (BPA) and bisphenol S (BPS) in breast milk samples. QuEChERS-based sample preparation procedure was optimized by evaluation of different clean-up sorbents including zirconium-based sorbents (Z-Sep and Z-Sep Plus) and primary secondary amine. Negligible matrix interference was observed for most of the analytes due to application of 45 mg Z-Sep or 45 mg Z-Sep + 5 mg Z-Sep Plus sorbents in d-SPE clean-up step. Acceptable analytical performance for the BPA and BPS was observed with recoveries percentage in the range of 70-92% and RSD less than 15%. The pilot study was performed by applying HPLC with diode-array detection, and optimized procedures were transferred to the LC triple-quadrupole MS system. LC with electrospray ionization and tandem MS operating in the multiple reaction monitoring mode provide high sensitivity and selectivity for trace analysis. The LODs were 0.10 and 0.54 ng/mL, and the LOQs were 0.20 and 1.35 ng/mL for BPS and BPA, respectively. The developed procedures were evaluated in terms for material collection obtained from women (inhabitants of Lublin, Poland). In 20 samples, bisphenol residues were detected at concentrations from 0.09 to 11.56 ng/mL.
基于分散固相萃取(d-SPE)和快速、简便、廉价、高效、耐用且安全(QuEChERS)方法,对不同的提取和净化方案进行了优化和比较,用于测定母乳样品中选定的双酚,如双酚A(BPA)和双酚S(BPS)。通过评估不同的净化吸附剂,包括锆基吸附剂(Z-Sep和Z-Sep Plus)和伯仲胺,对基于QuEChERS的样品制备程序进行了优化。由于在d-SPE净化步骤中使用了45 mg Z-Sep或45 mg Z-Sep + 5 mg Z-Sep Plus吸附剂,大多数分析物的基质干扰可忽略不计。观察到BPA和BPS的分析性能良好,回收率在70-92%范围内,相对标准偏差小于15%。采用二极管阵列检测的高效液相色谱法进行了初步研究,并将优化后的程序转移至液相色谱三重四极杆质谱系统。具有电喷雾电离和串联质谱的液相色谱在多反应监测模式下运行,为痕量分析提供了高灵敏度和选择性。BPS和BPA的检测限分别为0.10和0.54 ng/mL,定量限分别为0.20和1.35 ng/mL。对从波兰卢布林女性居民处收集的材料进行了评估,以评价所开发的程序。在20个样品中,检测到双酚残留浓度为0.09至11.56 ng/mL。