Determination of bisphenols released from packaging material is undoubtedly a difficult and tricky task, requiring the chemical analyst to develop an individual approach to obtain reliable analytical information.
QuECHERS (Quick, Easy, Cheap, Effective, Rugged, and Safe)/dispersive solid-phase extraction (d-SPE) technique and high performance liquid chromatography (HPLC) coupled with modern detection techniques such as diode-array detector (DAD), fluorescence detector (FLD) or tandem mass spectrometry (MS/MS) for the determination of bisphenols such as bisphenol A (BPA), bisphenol S (BPS), bisphenol F (BPF), bisphenol B (BPB), 2-[[4-[2-[4-(Oxiran-2-ylmethoxy)phenyl]propan-2yl]phenoxy] methyl]oxirane (BADGE), 3-[4-[2-[4-(Oxiran-2-ylmethoxy)phenyl]propan-2-yl]phenoxy]propane-1,2-diol (BADGEH2O), 3-[4-[2-[4-(2,3-Dihydroxypropoxy)phenyl]propan-2-yl]phenoxy]propane-1,2-diol (BADGE2H2O), 1-Chloro-3-[4-[2-[4-(3-chloro-2-hydroxypropoxy)phenyl] propan-2-yl]phenoxy]propan-2-ol (BADGE*2HCl) in human breast milk samples have been performed.
For the analysis of total analytes, prior to the extraction with acetonitrile, a deconjugation step was implemented in a tube by adding 1 mL of the enzymatic solution with the β-Glucuronidase to 5 mL of sample. The mix was homogenized and incubated for 17 h at 37°C. Ten milliliters of acetonitrile, and a QuEChERS salt packet with 4 g anhydrous MgSO4 and 1 g NaCl were added. During the d-SPE step the extract was transferred into tube with 30 mg Z-Sep and 50 mg PSA (and also 150 mg MgSO4 for LC-MS/MS analysis). MeOH-water (20:80, v/v) were added to the dry residue and the extract was reconstituted in 150 µL (25-fold analytes pre-concentration is achieved). Next bisphenols were identified by HPLC-DAD-FLD and quantified by LC-MS/MS equipment.
During the bisphenols HPLC-DAD-FLD analysis, from 6 min a reinforcement of 15 was used, which allowed analytes to be identified at 750 pg/mL. Application of LC-MS/MS allowed quantification of bisphenols in the range from 2.12 to 116.22 ng/mL in a total 27 human breast milk samples.
First QuEChERS/d-SPE coupled with HPLC-DAD-FLD or LC-MS/MS method for the quantification of bisphenols and its analogues in breast milk Faster and cheaper alternative to traditional extraction methods The method was applied for the first biomonitoring of bisphenols and its analogues in breast milk.
从包装材料中测定双酚是一项极具难度和挑战性的任务,这要求化学分析人员制定个性化的方法以获取可靠的分析信息。
采用 QuECHERS(快速、简单、廉价、有效、耐用、安全)/分散固相萃取(d-SPE)技术与高效液相色谱(HPLC)联用,结合二极管阵列检测器(DAD)、荧光检测器(FLD)或串联质谱(MS/MS)等现代检测技术,对双酚 A(BPA)、双酚 S(BPS)、双酚 F(BPF)、双酚 B(BPB)、2-[[4-[2-[4-(环氧乙烷-2-基甲氧基)苯基]丙-2-基]苯氧基]甲基]环氧乙烷(BADGE)、3-[4-[2-[4-(环氧乙烷-2-基甲氧基)苯基]丙-2-基]苯氧基]丙烷-1,2-二醇(BADGEH2O)、3-[4-[2-[4-(2,3-二羟丙氧基)苯基]丙-2-基]苯氧基]丙烷-1,2-二醇(BADGE2H2O)、1-氯-3-[4-[2-[4-(3-氯-2-羟丙氧基)苯基]丙-2-基]苯氧基]丙-2-醇(BADGE*2HCl)等双酚类物质进行了测定。
在采用乙腈提取之前,通过向 5 毫升样品中加入 1 毫升β-葡萄糖醛酸酶酶溶液,在管中进行去共轭化步骤。将混合物混合均匀,并在 37°C 下孵育 17 小时。向样品中加入 10 毫升乙腈和 4 克无水硫酸镁和 1 克氯化钠的 QuEChERS 盐包。在 d-SPE 步骤中,将提取物转移到装有 30 毫克 Z-Sep 和 50 毫克 PSA(以及 150 毫克硫酸镁用于 LC-MS/MS 分析)的管中。将 MeOH-水(20:80,v/v)加入到干燥残渣中,并将提取物在 150µL 中重新溶解(实现 25 倍的分析物预浓缩)。接下来,采用 HPLC-DAD-FLD 对双酚类物质进行鉴定,并采用 LC-MS/MS 设备进行定量。
在双酚类物质的 HPLC-DAD-FLD 分析中,从 6 分钟开始使用 15 倍的增强模式,从而可以在 750pg/mL 处鉴定出分析物。采用 LC-MS/MS 可以在 27 个人乳样本中对双酚类物质进行定量,其范围为 2.12 至 116.22ng/mL。
首次采用 QuEChERS/d-SPE 与 HPLC-DAD-FLD 或 LC-MS/MS 方法对母乳中的双酚及其类似物进行定量;与传统提取方法相比,该方法更快、更经济;首次将该方法应用于双酚及其类似物在母乳中的生物监测。