Suppr超能文献

使用支架取栓器对腓动脉内脱位的弹簧圈进行血管内取出。

Endovascular retrieval of a dislocated coil in the peroneal artery with a stent retriever.

作者信息

Nikoubashman Omid, Badenschier Rico, Müller Marguerite, Brockmann Carolin, Schubert Gerrit, Brockmann Marc-Alexander, Mühlenbruch Georg, Clusmann Hans Rainer, Wiesmann Martin

机构信息

Department of Radiology, Helios Klinikum Schwerin, Schwerin, Germany.

Department of Neuroradiology, University Hospital Aachen, Aachen, Germany.

出版信息

BJR Case Rep. 2016 Jan 19;2(1):20150278. doi: 10.1259/bjrcr.20150278. eCollection 2016.

Abstract

We present a patient who underwent successful removal of a fully detached platinum coil from the peroneal artery using a Solitaire stent retriever (Covidien, Irvine, CA) that is usually used in endovascular stroke treatment.

摘要

我们报告了一名患者,该患者使用通常用于血管内中风治疗的Solitaire支架取栓器(柯惠医疗公司,加利福尼亚州欧文市)成功地从腓动脉中取出了一个完全游离的铂线圈。