Xu Anping, Lei Jie, Li Jie, Chen Weidong, Zhou Yu, Zheng Ruoyang, Ji Ling
a Department of Laboratory Medicine , Peking University Shenzhen Hospital , Shenzhen , Guangdong , China.
b Department of Laboratory Medicine , Maternity and Child Healthcare Hospital of Nanshan District , Shenzhen , China.
Scand J Clin Lab Invest. 2018 Nov-Dec;78(7-8):621-625. doi: 10.1080/00365513.2018.1531298. Epub 2018 Oct 30.
Hemoglobin A (HbA) is a widely utilized biomarker for the diagnosis and management of diabetes mellitus. Here, we describe an α1-globin chain hemoglobin variant and investigate its effect on HbA measurement. A 26-year-old pregnant woman was suspected to harbor a hemoglobin variant following HbA measurement during a routine prenatal examination using D10 (Bio-Rad). An oral glucose tolerance test (OGTT) was performed using an AU5800 clinical chemistry system (Beckman Coulter). HbA was reanalyzed using VII-T 2.0 (Bio-Rad), Capillarys 2 Flex Piercing (C2FP, HbA program, Sebia), Premier Hb9210 (Trinity Biotech), and Cobas c501 (Cobas Tina-quant Hemoglobin A Gen.3). Glycated albumin (GA) level was also quantified using an enzymic method GA Kit (Lucica GA-L, Japan). Hemoglobin analysis was performed using high performance liquid chromatography on the Bio-Rad Variant II (β-thalassemia short program) and capillary electrophoresis (Capillarys 2 Flex Piercing, Hb program). Sanger sequencing of α and β genes was also conducted. HbA was initially measured at 16.0% (151 mmol/mol) using the D10 (Bio-Rad). Her OGTT result was normal. Subsequently, HbA values determined by VII-T 2.0, C2FP, Premier Hb9210, and Cobas c501 were 4.8% (29 mmol/mol), 4.9% (30 mmol/mol), 4.6% (27 mmol/mol), and 4.8% (29 mmol/mol), respectively. The glycated albumin level was 12.3% (reference: 10.8 ∼ 17.1%). Hemoglobin analyzed using CE and HPLC revealed an abnormal hemoglobin. By Sanger sequencing, we identified a transition mutation in the α1 gene Hb Shantou [α127(H10)Lys > Glu; HBA1: c.382 A > G]. Clinically silent variants may interfere with HbA determination by common methods.
血红蛋白A(HbA)是一种广泛用于糖尿病诊断和管理的生物标志物。在此,我们描述了一种α1 - 珠蛋白链血红蛋白变体,并研究其对HbA测量的影响。一名26岁的孕妇在常规产前检查中使用D10(伯乐公司)进行HbA测量后,被怀疑携带血红蛋白变体。使用AU5800临床化学系统(贝克曼库尔特公司)进行了口服葡萄糖耐量试验(OGTT)。使用VII - T 2.0(伯乐公司)、Capillarys 2 Flex Piercing(C2FP,HbA程序,赛比公司)、Premier Hb9210(三一生物科技公司)和Cobas c501(Cobas Tina - quant血红蛋白A Gen.3)重新分析HbA。糖化白蛋白(GA)水平也使用酶法GA试剂盒(Lucica GA - L,日本)进行定量。使用伯乐Variant II(β地中海贫血短程序)上的高效液相色谱法和毛细管电泳(Capillarys 2 Flex Piercing,Hb程序)进行血红蛋白分析。还对α和β基因进行了桑格测序。最初使用D