Song Xiaoxiao, Li Qiangqiang, Wu Zongfang, Xu Qian, Chen Dongyang, Jiang Qing
Department of Sports Medicine and Adult Reconstructive Surgery, Drum Tower Hospital, School of Medicine.
Department of Sports Medicine and Adult Reconstructive Surgery, Drum Tower, Hospital, Nanjing Medical University.
Medicine (Baltimore). 2018 Nov;97(44):e12672. doi: 10.1097/MD.0000000000012672.
The aim of this study was to evaluate the correlation between various anthropometric parameters and the graft diameter of the peroneus longus tendon (PLT).We retrospectively analyzed the data of 156 patients who underwent anterior cruciate ligament reconstruction (ACLR) with the PLT graft at our institution. Anthropometric parameters, including height, weight, gender, age, duration of injury, and preinjury activity levels, were recorded. t tests, correlation coefficients (Pearson r), and a multiple linear regression analysis were used to evaluate the influence of these anthropometric variables on the diameter of the graft obtained.The mean PLT graft diameter was 8.3 mm, and 21 patients (13.5%) had a diameter less than 8 mm; 85 patients (54.5%) had a diameter between 8 and 9 mm, and 50 patients (32.0%) had a diameter greater than or equal to 9 mm. The correlation analysis showed that height (P < .001), weight (P < .001), and duration of injury (P = .012) were significantly related to graft diameter. On the basis of these 3 predictors, the following regression equation was obtained: Diameter = 2.28 + 0.028height (cm) + 0.013weight (kg) + 0.289*duration of injury (0 or 1). Patients who were short and shin were more likely to own smaller graft diameters (<8 mm), especially the one ruptured his or her anterior cruciate ligament (ACL) over 3 months.Height, weight, and duration of injury were associated with the diameter of PLT. They are important preoperative information for surgeon about the size of PLT and can be used for alternative graft source planning and patient counseling.Level of evidence: IV.
本研究的目的是评估各种人体测量参数与腓骨长肌腱(PLT)移植物直径之间的相关性。我们回顾性分析了在本机构接受PLT移植物前交叉韧带重建(ACLR)的156例患者的数据。记录了包括身高、体重、性别、年龄、受伤时间和伤前活动水平在内的人体测量参数。采用t检验、相关系数(Pearson r)和多元线性回归分析来评估这些人体测量变量对所获移植物直径的影响。PLT移植物的平均直径为8.3毫米,21例患者(13.5%)的直径小于8毫米;85例患者(54.5%)的直径在8至9毫米之间,50例患者(32.0%)的直径大于或等于9毫米。相关性分析表明,身高(P<0.001)、体重(P<0.001)和受伤时间(P=0.012)与移植物直径显著相关。基于这3个预测因素,得到以下回归方程:直径=2.28 + 0.028×身高(厘米)+ 0.013×体重(千克)+ 0.289×受伤时间(0或1)。身材矮小且腿部较短的患者更有可能拥有较小的移植物直径(<8毫米),尤其是那些前交叉韧带(ACL)断裂超过3个月的患者。身高、体重和受伤时间与PLT的直径相关。它们是外科医生了解PLT大小的重要术前信息,可用于替代移植物来源规划和患者咨询。证据级别:IV。