晶状体和角膜在妊娠不同时期的密度。

Density of crystalline lens and cornea in different trimesters of pregnancy.

机构信息

Selcuk University Faculty of Medicine, Department of Opthalmology, Konya, Turkey.

Midyat State Hospital, Department of Ophthalmology, Mardin, Turkey.

出版信息

Cont Lens Anterior Eye. 2019 Jun;42(3):283-288. doi: 10.1016/j.clae.2018.10.016. Epub 2018 Nov 3.

Abstract

PURPOSE

To evaluate topographic measurements of the anterior segment and densitometric measurements of the cornea and lens by Pentacam HR in different trimesters of pregnancy.

METHODS

This prospective study included 150 healthy pregnant women in their first, second, or third trimester (Groups 1, 2 and 3, respectively) and 54 non-pregnant healthy women (Group 0). Topographic measurements, including central corneal thickness (CCT), corneal volume (CV), anterior chamber depth (ACD), corneal densitometry (CD) and lens densitometry (LD), were done with the Pentacam HR (Oculus, Wetzlar, Germany). The measurement results of the healthy pregnant women and non-pregnant healthy women were compared.

RESULTS

CD values were found in Group 1 to be 13.19, in Group 2 to be 13.16, in Group 3 to be 13.17 and in Group 0 to be 13.22 (p = 0.811). The mean Group 1, Group 2, Group 3 and Group 0 LD-horizontal was 5.40 ± 0.5, 5.47 ± 0.38, 5.53 ± 0.44, 5.36 ± 0.43, respectively. The mean Group 1, Group 2, Group 3 and Group 0 LD-vertical was 5.6 ± 0.43, 5.66 ± 0.32, 5.71 ± 0.40 and 5.5 ± 0.44, respectively. Area LD values were higher in the advanced trimester period, and the only statistically significant difference was between Group 3 and Group 0 (p = 0.025). The difference between three-dimensional (3D) and peak LD values was not statistically significant between the groups (p = 0.89 and p = 0.91, respectively).

DISCUSSION

The Pentacam HR seems to be an important option for the evaluation of LD, CD and topographic measurements of the anterior segment in pregnancy. In the present study, CD and LD, including LD-horizontal, LD-vertical, peak and 3D values, were not significantly different between pregnant women and non-pregnant women.

摘要

目的

通过 Pentacam HR 评估妊娠不同时期眼前节的地形学测量值和角膜及晶状体的密度测量值。

方法

本前瞻性研究纳入了 150 名处于孕早期、孕中期和孕晚期的健康孕妇(分别为组 1、组 2 和组 3)和 54 名非妊娠健康女性(组 0)。使用 Pentacam HR(德国 Oculus 公司)进行眼前节的地形学测量,包括中央角膜厚度(CCT)、角膜容积(CV)、前房深度(ACD)、角膜密度(CD)和晶状体密度(LD)。比较健康孕妇和非妊娠健康女性的测量结果。

结果

组 1 的 CD 值为 13.19,组 2 为 13.16,组 3 为 13.17,组 0 为 13.22(p=0.811)。组 1、组 2、组 3 和组 0 的 LD-水平均值分别为 5.40±0.5、5.47±0.38、5.53±0.44、5.36±0.43。组 1、组 2、组 3 和组 0 的 LD-垂直均值分别为 5.6±0.43、5.66±0.32、5.71±0.40、5.5±0.44。LD 面积在妊娠晚期较高,且仅组 3 与组 0 间差异有统计学意义(p=0.025)。组间 3D 和峰值 LD 值差异无统计学意义(p=0.89 和 p=0.91)。

讨论

Pentacam HR 似乎是评估妊娠期间 LD、CD 和眼前节地形学测量的重要选择。本研究中,孕妇与非孕妇的 CD 和 LD (包括 LD-水平、LD-垂直、峰值和 3D 值)差异均无统计学意义。