沙特阿拉伯王国无创通气的使用情况:一项全国性调查的结果。

Noninvasive ventilation utilization in the Kingdom of Saudi Arabia: Results of a national survey.

作者信息

AlAhmari Mohammed Dhafer, Al-Otaibi Hajed, Qutub Hatem, AlBalawi Ibrahim, Alqahtani Abdullah, Almasoudi Bandar

机构信息

Department of Respiratory Care, Prince Sultan Military College of Health Sciences, Dhahran, Saudi Arabia.

Department of Respiratory Care, King Abdulaziz University, Jeddah, Saudi Arabia.

出版信息

Ann Thorac Med. 2018 Oct-Dec;13(4):237-242. doi: 10.4103/atm.ATM_116_18.

Abstract

INTRODUCTION

Noninvasive ventilation (NIV) has been extensively used globally and is often administered as the first-line treatment. Currently, data regarding the utilization of NIV in the Kingdom of Saudi Arabia (KSA) is scarce. The present study aimed to assess and quantify the utilization of NIV in clinical practice across the KSA and investigate obstacles that may cause NIV underutilization.

METHODS

A web-based survey composed of a 31-item, self-administered questionnaire was developed and validated. The questionnaire was designed to obtain general information about each hospital, availability of NIV practice, use of NIV, and obstacles that can hinder NIV use in clinical settings; the survey was sent to senior respiratory therapists (RTs) of 76 hospitals. Descriptive statistics were used to analyze the data.

RESULTS

Sixty-one hospitals (80.3%) responded to the survey (47 governmental and 14 private). NIV was available in all hospitals and all the Intensive Care Units. The majority of RTs (85%) reported having a good experience with NIV, with a confidence rate of 60%; however, only 22% of the RTs had received formal training. Although NIV setup was the sole responsibility of RTs, only 69% participated in NIV management. Moreover, 72% of hospitals had an NIV setup protocol in place. However, 50% of them lacked a protocol for NIV failure. NIV protocols for specific indications were present in 64% of the hospitals: 47.2% for monitoring and 42% for weaning. The perceived efficiency of NIV practice was low in the medical wards, with a <49% success rate in 39% of the hospitals. Shortage of staff and lack of formal training were the most common reasons for NIV underutilization.

CONCLUSION

The efficiency of NIV in the KSA was low. The RTs expressed moderate confidence in administering NIV. Lack of appropriate exposure and formal training could have negative impacts on NIV practice.

摘要

引言

无创通气(NIV)在全球范围内已被广泛使用,并且经常作为一线治疗方法。目前,关于沙特阿拉伯王国(KSA)无创通气使用情况的数据很少。本研究旨在评估和量化无创通气在沙特阿拉伯王国临床实践中的使用情况,并调查可能导致无创通气使用不足的障碍。

方法

开发并验证了一份基于网络的调查问卷,该问卷由31个项目组成,为自填式问卷。该问卷旨在获取每家医院的一般信息、无创通气实践的可用性、无创通气的使用情况以及可能阻碍临床环境中无创通气使用的障碍;该调查发送给了76家医院的高级呼吸治疗师(RTs)。使用描述性统计分析数据。

结果

61家医院(80.3%)回复了调查(47家政府医院和14家私立医院)。所有医院和所有重症监护病房都有无创通气设备。大多数呼吸治疗师(85%)报告在无创通气方面有良好的经验,置信率为60%;然而,只有22%的呼吸治疗师接受过正规培训。尽管无创通气设备的设置是呼吸治疗师的唯一职责,但只有69%的人参与了无创通气管理。此外,72%的医院制定了无创通气设备设置方案。然而,其中50%的医院缺乏无创通气失败的方案。64%的医院有针对特定适应症的无创通气方案:47.2%用于监测,42%用于撤机。在医疗病房中,无创通气实践的感知效率较低,39%的医院成功率低于49%。人员短缺和缺乏正规培训是无创通气使用不足的最常见原因。

结论

沙特阿拉伯王国无创通气的效率较低。呼吸治疗师在实施无创通气方面表现出中等信心。缺乏适当的接触和正规培训可能会对无创通气实践产生负面影响。