Suppr超能文献

短而中度粗糙种植体支持的单冠的长期随访:一项前瞻性 10 年队列研究。

Long-term follow-up of single crowns supported by short, moderately rough implants-A prospective 10-year cohort study.

机构信息

Department of Biomedical and Neuromotorial Science, University of Bologna, Bologna, Italy.

University of Berne, Berne, Switzerland.

出版信息

Clin Oral Implants Res. 2018 Dec;29(12):1212-1219. doi: 10.1111/clr.13386. Epub 2018 Dec 6.

Abstract

OBJECTIVES

To evaluate prospectively the clinical and radiographic outcomes after ten years of short (6 mm) implants with a moderately rough surface supporting single crowns in the posterior region.

MATERIAL AND METHODS

Forty 6 mm modified sandblasted large-grit acid-etched (mod-SLA), soft tissue level implants were installed in the distal segments of 35 consecutive patients. After 6 weeks of healing, abutments were tightened, and single porcelain-fused-to-metal crowns were cemented. Implant survival, marginal bone loss, and clinical crown/implant ratio were evaluated at various time intervals up to 10 years after loading.

RESULTS

Two out of the 40 implants were lost before loading, one implant was lost after 7 years because of peri-implantitis. One patient with two implants died and was excluded from analysis. Two patients did not come at the 10-year follow-up and were considered as drop out (2 implants). The survival rate was 91.7% (n = 36). Thirty-three implants were available for marginal bone loss evaluation. A mean marginal bone loss after 10 years of function was 0.8 ± 0.7 mm. Between 5 and 10 years, the loss was 0.2 ± 0.4 mm. No technical complications were registered during the 10-year period. The clinical crown/implant ratio increased with time from 1.6 at the delivery of the prosthesis to 2.0 after 10 years of loading with no increase between 5 and 10 years.

CONCLUSION

Short (6 mm) implants with a moderately rough surface supporting single crowns in the posterior region and loaded after 6-7 weeks maintained full function for at least 10 years with low marginal bone resorption.

摘要

目的

前瞻性评估使用中度粗糙表面的 6mm 短种植体在 10 年后支持后牙区单冠的临床和影像学结果。

材料和方法

将 40 颗 6mm 改良喷砂大颗粒酸蚀(mod-SLA)软组织水平种植体植入 35 名连续患者的远中段。愈合 6 周后,拧紧基台,粘结单瓷熔附金属冠。在负载后 10 年内的不同时间间隔评估种植体存活率、边缘骨丧失和临床冠/种植体比值。

结果

在负载前有 2 颗种植体脱落,其中 1 颗种植体在 7 年后因种植体周围炎而脱落。1 名患者因 2 颗种植体死亡而被排除在分析之外。有 2 名患者未进行 10 年随访,被视为脱落(2 颗种植体)。存活率为 91.7%(n=36)。33 颗种植体可用于评估边缘骨丧失。功能 10 年后平均边缘骨丧失为 0.8±0.7mm。在 5 至 10 年内,损失为 0.2±0.4mm。在 10 年期间未记录到任何技术并发症。临床冠/种植体比值随时间从修复体交付时的 1.6 增加到负载 10 年后的 2.0,在 5 至 10 年内没有增加。

结论

在 6-7 周后负载的后牙区使用中度粗糙表面的 6mm 短种植体支持单冠,在至少 10 年内保持完全功能,边缘骨吸收低。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验