Horton Sarah, Dumond Patrick
Annu Int Conf IEEE Eng Med Biol Soc. 2018 Jul;2018:1849-1852. doi: 10.1109/EMBC.2018.8512640.
Coiled polymer actuators are fabricated by heating a twisted nylon fishing filament. This paper provides a detailed review of their manufacturing process and proposes a method to manufacture these actuators consistently to improve the predictability of their behavior. Two devices are presented: a device that prepares consistent filament sections, and another that twists and coils the filament. Seven successful actuators are produced using the proposed method. The behavior of the manufactured actuators is characterized using a tensile test on an Instron universal testing machine. Fluctuations in the observed force are believed to be due to inconsistencies in resistance wire lengths.
螺旋聚合物致动器是通过加热扭曲的尼龙钓鱼线制成的。本文详细回顾了它们的制造过程,并提出了一种始终如一地制造这些致动器的方法,以提高其行为的可预测性。介绍了两种装置:一种用于制备一致的细丝段的装置,另一种用于使细丝扭曲和缠绕的装置。使用所提出的方法生产了七个成功的致动器。使用英斯特朗万能试验机进行拉伸试验,对制造的致动器的行为进行了表征。观察到的力的波动被认为是由于电阻丝长度不一致所致。