Nishii Tatsuya, Kotoku Akiyuki, Hori Yoshiro, Matsuzaki Yuji, Watanabe Yoshiaki, Morita Yoshiaki, Kono Atsushi K, Matsuda Hitoshi, Fukuda Tetsuya
Department of Radiology, National Cerebral and Cardiovascular Center, 5-7-1, Fujishiro-dai, Suita, Osaka, 565-8565, Japan.
Departments of Vascular Surgery, National Cerebral and Cardiovascular Center, Osaka, Japan.
Neuroradiology. 2019 Mar;61(3):305-311. doi: 10.1007/s00234-018-2136-8. Epub 2018 Nov 21.
The reliability of assessment of the artery of Adamkiewicz before the aortic repair is highly dependent on the display of the continuity of this artery with the aorta, mainly around the vertebral pedicle, by computed tomography angiography (CTA). We hypothesized that the sharp filter kernel can improve visualization of this continuity of the vessel structure because of its edge enhancement and high-spatial resolution. This study was performed to compare the subjective and objective image quality of spinal CTA reconstructed with sharp and smooth filter kernels.
We retrospectively reviewed 40 consecutive patients who had undergone 80-kV CTA to detect the artery of Adamkiewicz before aortic repair. We measured the CT number and the contrast-to-noise ratio of the anterior spinal artery to the spinal cord. Furthermore, the continuity of the artery of Adamkiewicz was evaluated using a 3-point scale (2 points, absolute; 0 points, undetectable).
CTA with the sharp filter kernel showed a significantly higher CT number and contrast-to-noise ratio of the spinal artery than did CTA with the smooth filter kernel (P < .001 for both). Moreover, the sharp filter kernel showed a significantly higher continuity of the artery of Adamkiewicz with the aorta than did the smooth filter kernel (P < .001).
The sharp filter kernel significantly improved the image quality in low-tube-voltage CTA for the assessment of the artery of Adamkiewicz. Thus, CTA with the sharp filter kernel can generate a high-confidence level in the evaluation of the artery of Adamkiewicz.
在主动脉修复术前对Adamkiewicz动脉进行评估的可靠性高度依赖于通过计算机断层血管造影(CTA)显示该动脉与主动脉的连续性,主要是在椎弓根周围。我们推测锐化滤波核因其边缘增强和高空间分辨率可改善血管结构连续性的可视化。本研究旨在比较使用锐化和平滑滤波核重建的脊柱CTA的主观和客观图像质量。
我们回顾性分析了40例连续接受80 kV CTA检查以在主动脉修复术前检测Adamkiewicz动脉的患者。我们测量了脊髓前动脉的CT值和对比噪声比。此外,使用3分制评估Adamkiewicz动脉的连续性(2分,明确;0分,无法检测到)。
与使用平滑滤波核的CTA相比,使用锐化滤波核的CTA显示脊髓动脉的CT值和对比噪声比显著更高(两者P均<0.001)。此外,与平滑滤波核相比,锐化滤波核显示Adamkiewicz动脉与主动脉的连续性显著更高(P<0.001)。
锐化滤波核显著改善了低管电压CTA用于评估Adamkiewicz动脉的图像质量。因此,使用锐化滤波核的CTA在评估Adamkiewicz动脉时可产生高置信度。