自适应统计迭代重建对肿瘤患者CT影像组学特征的影响

Influence of Adaptive Statistical Iterative Reconstructions on CT Radiomic Features in Oncologic Patients.

作者信息

Caruso Damiano, Zerunian Marta, Pucciarelli Francesco, Bracci Benedetta, Polici Michela, D'Arrigo Benedetta, Polidori Tiziano, Guido Gisella, Barbato Luca, Polverari Daniele, Benvenga Antonella, Iannicelli Elsa, Laghi Andrea

机构信息

Radiology Unit, Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Sant'Andrea University Hospital, Via di Grottarossa, 1035-1039, 00189 Rome, Italy.

出版信息

Diagnostics (Basel). 2021 May 31;11(6):1000. doi: 10.3390/diagnostics11061000.

Abstract

Iterative reconstructions (IR) might alter radiomic features extraction. We aim to evaluate the influence of Adaptive Statistical Iterative Reconstruction-V (ASIR-V) on CT radiomic features. Patients who underwent unenhanced abdominal CT (Revolution Evo, GE Healthcare, USA) were retrospectively enrolled. Raw data of filtered-back projection (FBP) were reconstructed with 10 levels of ASIR-V (10-100%). CT texture analysis (CTTA) of liver, kidney, spleen and paravertebral muscle for all datasets was performed. Six radiomic features (mean intensity, standard deviation (SD), entropy, mean of positive pixel (MPP), skewness, kurtosis) were extracted and compared between FBP and all ASIR-V levels, with and without altering the spatial scale filter (SSF). CTTA of all organs revealed significant differences between FBP and all ASIR-V reconstructions for mean intensity, SD, entropy and MPP (all < 0.0001), while no significant differences were observed for skewness and kurtosis between FBP and all ASIR-V reconstructions (all > 0.05). A per-filter analysis was also performed comparing FBP with all ASIR-V reconstructions for all six SSF separately (SSF0-SSF6). Results showed significant differences between FBP and all ASIR-V reconstruction levels for mean intensity, SD, and MPP (all filters < 0.0315). Skewness and kurtosis showed no differences for all comparisons performed (all > 0.05). The application of incremental ASIR-V levels affects CTTA across various filters. Skewness and kurtosis are not affected by IR and may be reliable quantitative parameters for radiomic analysis.

摘要

迭代重建(IR)可能会改变影像组学特征提取。我们旨在评估自适应统计迭代重建-V(ASIR-V)对CT影像组学特征的影响。对接受腹部平扫CT(美国通用电气医疗集团的Revolution Evo)的患者进行回顾性纳入。使用10个水平的ASIR-V(10%-100%)对滤波反投影(FBP)的原始数据进行重建。对所有数据集的肝脏、肾脏、脾脏和椎旁肌进行CT纹理分析(CTTA)。提取六个影像组学特征(平均强度、标准差(SD)、熵、阳性像素均值(MPP)、偏度、峰度),并在FBP与所有ASIR-V水平之间进行比较,比较时分别采用和不采用改变空间尺度滤波器(SSF)的情况。所有器官的CTTA显示,FBP与所有ASIR-V重建在平均强度、SD、熵和MPP方面存在显著差异(均P<0.0001),而FBP与所有ASIR-V重建在偏度和峰度方面未观察到显著差异(均P>0.05)。还分别对FBP与所有ASIR-V重建针对所有六个SSF(SSF0-SSF6)进行了逐滤波器分析。结果显示,FBP与所有ASIR-V重建水平在平均强度、SD和MPP方面存在显著差异(所有滤波器P<0.0315)。在所有进行的比较中,偏度和峰度均无差异(均P>0.05)。增加ASIR-V水平的应用会影响不同滤波器下的CTTA。偏度和峰度不受IR影响,可能是影像组学分析中可靠的定量参数。