Department of Dental Biomaterials, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
Department of Endodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
Dent Mater. 2019 Jan;35(1):185-193. doi: 10.1016/j.dental.2018.11.019. Epub 2018 Dec 1.
To evaluate the influence of titanium tetrafluoride (TiF) incorporation on the physicochemical and antibacterial properties of Biodentine (BD; Septodont, Saint Maur des Faussés, France) as an intraorfice barrier material.
Three different proportions of TiF powder were used with BD; 1wt%, 2wt%, and 3wt%; respectively. BD without TiF addition was used as the control group. The setting time (ST) was determined using Gillmore needle apparatus. Diametral tensile strength (DTS) and fracture resistance were measured in a universal testing machine. Solubility was assessed using mass variation after 7days water storage. The hardness test was conducted using Vickers microhardness tester. The antibacterial activity was assessed using direct contact test against Enterococcus faecalis. Radiopacity was assessed and expressed in thickness of aluminum. Surface topography and elemental composition of modified BD were also assessed. The pH of soaking water was measured up to 168h. Data of tested properties were analyzed using one-way analysis of variance, the paired t-test, two-way repeated measures analysis of variance, and Tukey post hoc tests (P<0.05).
BD-incorporating 2wt% TiF revealed the highest surface microhardness, DTS, and fracture resistance compared with the unmodified group (P<0.001). Higher concentrations of TiF (3wt%) compromised the solubility and prolonged the ST of BD (P<0.05). Bacterial growth of BD-incorporating TiF was significantly reduced when compared with the control group (P<0.05). The tested materials induced alkalization of the soaking water that decreased with time.
Biodentine-incorporating TiF (1wt% and 2wt%) is a promising intraorfice barrier material with enhanced physicochemical and antibacterial properties.
评估四氟化钛(TiF)的掺入对 Biodentine(BD;法国圣莫里斯德法斯的 Septodont)作为口腔内屏障材料的理化性能和抗菌性能的影响。
使用三种不同比例的 TiF 粉末与 BD 混合;分别为 1wt%、2wt%和 3wt%。未添加 TiF 的 BD 用作对照组。使用 Gillmore 针设备测定凝固时间(ST)。在万能试验机上测量直径拉伸强度(DTS)和断裂阻力。通过 7 天水储存后的质量变化评估溶解度。使用维氏显微硬度计进行硬度测试。通过与粪肠球菌的直接接触试验评估抗菌活性。评估并以铝厚度表示射线不透性。还评估了改性 BD 的表面形貌和元素组成。测量浸泡水的 pH 值直至 168 小时。使用单向方差分析、配对 t 检验、双向重复测量方差分析和 Tukey 事后检验分析测试性能的数据(P<0.05)。
与未改性组相比,掺入 2wt%TiF 的 BD 显示出最高的表面显微硬度、DTS 和断裂阻力(P<0.001)。更高浓度的 TiF(3wt%)会降低 BD 的溶解度并延长 ST(P<0.05)。与对照组相比,掺入 TiF 的 BD 的细菌生长明显减少(P<0.05)。测试材料诱导浸泡水碱化,随着时间的推移而减少。
掺入 TiF(1wt%和 2wt%)的 Biodentine 是一种有前途的口腔内屏障材料,具有增强的理化性能和抗菌性能。